Key features
- VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity*
- True RMS for accurate AC measurements on non-linear loads
- A large backlit display allows for easy visibility in low-lit areas
- Record signal fluctuations using the Min/Max function
- Diode test for testing general-purpose germanium, silicon, and power diodes
- Integral holster with probe holders for easy storage
- Auto and Manual ranging for added user functionality
- Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety
- The optional TPAK magnetic hanger allows the user hands-free flexibility
Product overview: Fluke 113 Digital Multimeter
The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. LoZ low impedance measurements also block ghost voltages induced by nearby conductors. *Be advised that LoZ low impedance measurements present a low load to a circuit protected by an RCD, which can cause the RCD to trip. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
Specifications: Fluke 113 Digital Multimeter
Specifications | ||
VCHEK1 2 3 | Range | 6.000 V / 60.00 V / 600.0 V |
Resolution | 0.001 V / 0.01 V/ 0.1 V | |
Accuracy | DC, 45 to 500 Hz: 2.0% + 3 500 Hz to 1 kHz: 4.0% + 3 |
|
Diode test4 | Range | 2.000 V |
Resolution | 0.001 V | |
Accuracy | 2.0% + 3 | |
Continuity4 | Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer |
Ω4 | Range | 600.0 Ω / 6.000 kΩ / 60.00 kΩ |
Resolution | 0.1 Ω / 0.001 kΩ / 0.01 kΩ | |
Accuracy | 0.9% + 2 / 0.9% + 1 / 0.9% + 1 | |
Capacitance4 | Range | 1000 nF / 10.00 μF / 100.0 μF / 9999 μF |
Resolution | 1 nF / 0.01 μF / 0.1 μF / 1 μF | |
Accuracy | 1.9% + 2 100 μF - 1000 μF: 1.9% + 2 1000 μF: 5% + 20 |
|
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. |
||
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Display | 3 3/4-digits, 6000 counts, updates 4/sec | |
Operating temperature | -10°C to 50°C (14°F to 122°F) | |
Storage temperature | -40°C to 60°C (-22°F to 140°F) | |
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating altitude | 2,000 m | |
Storage altitude | 10,000 m | |
Relative humidity | 95% to 30°C 75% to 40°C 45% to 50°C |
|
Battery type | 9 Volt Alkaline, ANSI 1604A / IEC 6F22 | |
Battery life | Alkaline: 300 hours typical, without backlight | |
Shock | 1 Meter drop per IEC 61010–1–2001 | |
Vibration | Per MIL-PRF-28800 for Class 2 instrument | |
Size (H x W x L) | 167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in) | |
Weight | 13.0 oz (404 g) | |
Safety | Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1 | |
EMI regulations | Complies with FCC Part 15, Class B | |
Specifications | ||
VCHEK | Input impedance (nominal) | ~3 kΩ < 300 pF |
VCHEK | Common mode rejection ratio (1 kΩ unbalanced) |
> 60 dB at DC, 50 or 60 Hz |
Ω | Open circuit test voltage | < 2.7 VDC |
Full scale voltage | < 0.7 VDC | |
Diode test | Open circuit test voltage | 2.7 VDC |
Full scale voltage | 2.000 VDC | |
Ω | Short circuit current | < 350 μA |
Diode test | Short circuit current | < 1.0 mA |
Includes
- Fluke TL75 test leads
- Holster
- Users manual
- and 9 V battery (installed
Manuals
- 113 | Instruction sheet
- 113 | Instruction sheet supplement
- 113 | Calibration information
- 113 | Calibration information supplement
- 117, 116,115,114,113 and 110 Plus | Statement of memory volatility
Data sheets
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
Key features
- VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity*
- True RMS for accurate AC measurements on non-linear loads
- A large backlit display allows for easy visibility in low-lit areas
- Record signal fluctuations using the Min/Max function
- Diode test for testing general-purpose germanium, silicon, and power diodes
- Integral holster with probe holders for easy storage
- Auto and Manual ranging for added user functionality
- Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety
- The optional TPAK magnetic hanger allows the user hands-free flexibility
Product overview: Fluke 113 Digital Multimeter
The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. LoZ low impedance measurements also block ghost voltages induced by nearby conductors. *Be advised that LoZ low impedance measurements present a low load to a circuit protected by an RCD, which can cause the RCD to trip. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
Specifications: Fluke 113 Digital Multimeter
Specifications | ||
VCHEK1 2 3 | Range | 6.000 V / 60.00 V / 600.0 V |
Resolution | 0.001 V / 0.01 V/ 0.1 V | |
Accuracy | DC, 45 to 500 Hz: 2.0% + 3 500 Hz to 1 kHz: 4.0% + 3 |
|
Diode test4 | Range | 2.000 V |
Resolution | 0.001 V | |
Accuracy | 2.0% + 3 | |
Continuity4 | Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer |
Ω4 | Range | 600.0 Ω / 6.000 kΩ / 60.00 kΩ |
Resolution | 0.1 Ω / 0.001 kΩ / 0.01 kΩ | |
Accuracy | 0.9% + 2 / 0.9% + 1 / 0.9% + 1 | |
Capacitance4 | Range | 1000 nF / 10.00 μF / 100.0 μF / 9999 μF |
Resolution | 1 nF / 0.01 μF / 0.1 μF / 1 μF | |
Accuracy | 1.9% + 2 100 μF - 1000 μF: 1.9% + 2 1000 μF: 5% + 20 |
|
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range. 4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. |
||
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Display | 3 3/4-digits, 6000 counts, updates 4/sec | |
Operating temperature | -10°C to 50°C (14°F to 122°F) | |
Storage temperature | -40°C to 60°C (-22°F to 140°F) | |
Temperature coefficient | 0.1 x (specified accuracy) / °C (< 18°C or > 28°C) | |
Operating altitude | 2,000 m | |
Storage altitude | 10,000 m | |
Relative humidity | 95% to 30°C 75% to 40°C 45% to 50°C |
|
Battery type | 9 Volt Alkaline, ANSI 1604A / IEC 6F22 | |
Battery life | Alkaline: 300 hours typical, without backlight | |
Shock | 1 Meter drop per IEC 61010–1–2001 | |
Vibration | Per MIL-PRF-28800 for Class 2 instrument | |
Size (H x W x L) | 167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in) | |
Weight | 13.0 oz (404 g) | |
Safety | Complies with ANSI / ISA 82.02.01 (61010–1) 2004, CAN / CSA-C22.2 No 61010-1-04, UL 61010–1 (2004) and IEC / EN 61010–1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326–1 | |
EMI regulations | Complies with FCC Part 15, Class B | |
Specifications | ||
VCHEK | Input impedance (nominal) | ~3 kΩ < 300 pF |
VCHEK | Common mode rejection ratio (1 kΩ unbalanced) |
> 60 dB at DC, 50 or 60 Hz |
Ω | Open circuit test voltage | < 2.7 VDC |
Full scale voltage | < 0.7 VDC | |
Diode test | Open circuit test voltage | 2.7 VDC |
Full scale voltage | 2.000 VDC | |
Ω | Short circuit current | < 350 μA |
Diode test | Short circuit current | < 1.0 mA |
Includes
- Fluke TL75 test leads
- Holster
- Users manual
- and 9 V battery (installed
Manuals
- 113 | Instruction sheet
- 113 | Instruction sheet supplement
- 113 | Calibration information
- 113 | Calibration information supplement
- 117, 116,115,114,113 and 110 Plus | Statement of memory volatility
Data sheets
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.