PRODUCT OVERVIEW
Accuracy and traceability for infrared measurements
Now it’s easy to increase your IR temperature measurement accuracy with the new 4180/81 Hart Scientific Precision Infrared Calibrators from Fluke Calibration. These calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimises size of source effect errors. In addition, these calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.
New accredited performance for point-and-shoot calibrations
- Calibrated radiometrically for meaningful, consistent results.
- Accredited calibration included
- Accurate, reliable performance from –15 °C to 500 °C
- Large target size of 152 mm (6 in) is required for calibrating most thermometers.
- Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
- Intuitive, easy-to-read display that indicates when temperature is stable.
FEATURES
The 4180 Series of Precision Infrared Calibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations. This is the perfect solution for any infrared thermometer or thermal imager within its temperature range.
The 4180 reaches temperatures from –15 °C to 120 °C and the 4181 has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.
In addition, with accuracies as good as ±0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.
MODELS
IR Calibrator, 152 mm (6 in), -15°C to 120°C
Includes:
- 4180 IR calibrator
- Report of calibration (NVLAP accredited)
- Power cord
- User’s guide
- Documentation CD
- Target cover
- Serial cable
IR Calibrator, 152 mm (6 in), 35°C to 500°C
Includes:
- 4181 IR calibrator
- Report of calibration (NVLAP accredited)
- Power cord
- User’s guide
- Documentation CD
- Target cover
- Serial cable
SPECIFICATIONS
Specifications | 4180 | 4181 |
Temperature range (@ 23°C ambient, 0.95 emissivity) | –15°C to 120°C | 35°C to 500°C |
Display accuracy1 | ±0.40°C at –15°C ±0.40°C at 0°C ±0.50°C at 50°C ±0.50°C at 100°C ±0.55°C at 120°C |
±0.35°C at 35°C ±0.50°C at 100°C ±0.70°C at 200°C ±1.20°C at 350°C ±1.60°C at 500°C |
Stability | ±0.10°C at –15°C ±0.05°C at 0°C ±0.10°C at 120°C |
±0.05°C at 35°C ±0.20°C at 200°C ±0.40°C at 500°C |
Uniformity (5.0 in dia of center of target)2 | ±0.15°C at –15°C ±0.10°C at 0°C ±0.25°C at 120°C |
±0.10°C at 35°C ±0.50°C at 250°C ±1.00°C at 500°C |
Uniformity (2.0 in dia of center of target)2 | ±0.10°C at -15°C ±0.10°C at 0°C ±0.20°C at 120°C |
±0.10°C at 35°C ±0.25°C at 250°C ±0.50°C at 500°C |
Heating time | 15 min: –15°C to 120°C 14 min: 23°C to 120°C |
20 min: 35°C to 500°C |
Cooling time | 15 min: 120°C to 23°C 20 min: 23°C to –15°C |
100 min: 500°C to 35°C 40 min: 500°C to 100°C |
Stabilization time | 10 minutes | 10 minutes |
Nominal emissivity3 | 0.95 | 0.95 |
Thermometer emissivity compensation | 0.9 to 1.0 | 0.9 to 1.0 |
Target diameter | 152.4 mm (6 in) | 152.4 mm (6 in) |
Computer interface | RS-232 | RS-232 |
Power | 115 V AC (±10%), 6.3 A, 50/60 Hz, 630 W 230 V AC (±10%), 3.15 A, 50/60 Hz, 630 W |
115 V AC (±10%), 10 A, 50/60 Hz, 1000 W 230 V AC (±10%), 5 A, 50/60 Hz, 1000 W |
Fuse(s) | 115 V AC 6.3 A, 250 V, slow blow 230 V AC 3.15 A, 250 V, T |
115 V AC 10 A, 250 V, fast blow 230 V AC 5 A, 250 V, F |
Size (H x W x D) | 356 x 241 x 216 mm (14 x 9.5 x 8.5 in) |
356 x 241 x 216 mm (14 x 9.5 x 8.5 in) |
Weight | 9.1 kg (20 lb) | 9.5 kg (21 lb) |
1. For 8 um to 14 um spectral band thermometers with emissivity set between 0.9 and 1.0 2. The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature. 3. The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties. |
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 3109525, 3109569)
PRODUCT OVERVIEW
Accuracy and traceability for infrared measurements
Now it’s easy to increase your IR temperature measurement accuracy with the new 4180/81 Hart Scientific Precision Infrared Calibrators from Fluke Calibration. These calibrators give more consistent, accurate and reliable calibrations because emissivity is radiometrically calibrated, and the target size minimises size of source effect errors. In addition, these calibrators simplify calibration because they uniquely compensate for errors caused by thermometer emissivity settings.
New accredited performance for point-and-shoot calibrations
- Calibrated radiometrically for meaningful, consistent results.
- Accredited calibration included
- Accurate, reliable performance from –15 °C to 500 °C
- Large target size of 152 mm (6 in) is required for calibrating most thermometers.
- Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
- Intuitive, easy-to-read display that indicates when temperature is stable.
FEATURES
The 4180 Series of Precision Infrared Calibrators for infrared thermometers and thermal imagers is fast, accurate, and easy to use. It comes with an accredited calibration from one of the world’s most trusted temperature calibration laboratories, sample calibration procedures for Fluke thermometers built right in and everything you need to get started making high-quality infrared thermometer calibrations. This is the perfect solution for any infrared thermometer or thermal imager within its temperature range.
The 4180 reaches temperatures from –15 °C to 120 °C and the 4181 has a temperature range from 35 °C to 500 °C. Uniformity is important in infrared temperature calibration work because an infrared thermometer will “see” as much as the entire target when placed at the appropriate calibration distance.
In addition, with accuracies as good as ±0.35 °C the 4180 Series can meet its specifications without additional emissivity-related corrections, leading to legitimate test uncertainty ratios (TUR) as good as 4:1.
MODELS
IR Calibrator, 152 mm (6 in), -15°C to 120°C
Includes:
- 4180 IR calibrator
- Report of calibration (NVLAP accredited)
- Power cord
- User’s guide
- Documentation CD
- Target cover
- Serial cable
IR Calibrator, 152 mm (6 in), 35°C to 500°C
Includes:
- 4181 IR calibrator
- Report of calibration (NVLAP accredited)
- Power cord
- User’s guide
- Documentation CD
- Target cover
- Serial cable
SPECIFICATIONS
Specifications | 4180 | 4181 |
Temperature range (@ 23°C ambient, 0.95 emissivity) | –15°C to 120°C | 35°C to 500°C |
Display accuracy1 | ±0.40°C at –15°C ±0.40°C at 0°C ±0.50°C at 50°C ±0.50°C at 100°C ±0.55°C at 120°C |
±0.35°C at 35°C ±0.50°C at 100°C ±0.70°C at 200°C ±1.20°C at 350°C ±1.60°C at 500°C |
Stability | ±0.10°C at –15°C ±0.05°C at 0°C ±0.10°C at 120°C |
±0.05°C at 35°C ±0.20°C at 200°C ±0.40°C at 500°C |
Uniformity (5.0 in dia of center of target)2 | ±0.15°C at –15°C ±0.10°C at 0°C ±0.25°C at 120°C |
±0.10°C at 35°C ±0.50°C at 250°C ±1.00°C at 500°C |
Uniformity (2.0 in dia of center of target)2 | ±0.10°C at -15°C ±0.10°C at 0°C ±0.20°C at 120°C |
±0.10°C at 35°C ±0.25°C at 250°C ±0.50°C at 500°C |
Heating time | 15 min: –15°C to 120°C 14 min: 23°C to 120°C |
20 min: 35°C to 500°C |
Cooling time | 15 min: 120°C to 23°C 20 min: 23°C to –15°C |
100 min: 500°C to 35°C 40 min: 500°C to 100°C |
Stabilization time | 10 minutes | 10 minutes |
Nominal emissivity3 | 0.95 | 0.95 |
Thermometer emissivity compensation | 0.9 to 1.0 | 0.9 to 1.0 |
Target diameter | 152.4 mm (6 in) | 152.4 mm (6 in) |
Computer interface | RS-232 | RS-232 |
Power | 115 V AC (±10%), 6.3 A, 50/60 Hz, 630 W 230 V AC (±10%), 3.15 A, 50/60 Hz, 630 W |
115 V AC (±10%), 10 A, 50/60 Hz, 1000 W 230 V AC (±10%), 5 A, 50/60 Hz, 1000 W |
Fuse(s) | 115 V AC 6.3 A, 250 V, slow blow 230 V AC 3.15 A, 250 V, T |
115 V AC 10 A, 250 V, fast blow 230 V AC 5 A, 250 V, F |
Size (H x W x D) | 356 x 241 x 216 mm (14 x 9.5 x 8.5 in) |
356 x 241 x 216 mm (14 x 9.5 x 8.5 in) |
Weight | 9.1 kg (20 lb) | 9.5 kg (21 lb) |
1. For 8 um to 14 um spectral band thermometers with emissivity set between 0.9 and 1.0 2. The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature. 3. The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties. |
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.