(item no. 3055440)
PRODUCT OVERVIEW
High-temperature secondary standards
- Range to 661°C
- Meets all ITS-90 requirements for resistance ratios
- Rtp drift < 20 mK after 500 hours at 661°C
- Calibrated accuracy of ± 0.006 °C at 0 °C
Fluke Calibration's high-temp secondary standards fill the gap between affordable, but temperature-limited secondary PRTs (platinum resistance thermometers) and more expensive, highly accurate SPRTs (standard platinum resistance thermometers).
If you’re using block calibrators, furnaces, or temperature points above normal PRT (platinum resistance thermometer) temperatures (420 °C), then these two PRTs are for you. The Fluke 5626 is nominally 100 Ω and the 5628 (formerly Hart Scientific) is nominally 25.5 Ω. Both instruments have a temperature range of –200 °C to 661 °C. They make great working or check standards for calibration work up to the aluminum point.
Using a regular PRT at temperatures above 500 °C exposes the platinum to contamination. If the PRT is used as a reference or calibration standard, contamination is a major problem. SPRTs (standard platinum resistance thermometers), which are more expensive and delicate, can handle the higher temperatures, but with greater risk to the instrument due to shock, contamination, or mishandling. The 5626 and 5628 are designed to reduce the contamination risk through the use of internal protection while not impairing performance.
In addition to the right measurement performance and durability, a PRT for secondary applications should be priced affordably. Fluke Calibration’s new PRTs are inexpensive and come with an accredited calibration. The calibration comes complete with ITS-90 constants and a resistance-versus-temperature table.
Check the temperature range, check the stability, check the price! Who else gives you this much quality, performance, and value for your money? No one!
SPECIFICATIONS
Temperature Range |
–200 °C to 661 °C |
Handle Temp. |
0 °C to 80 °C |
RTPW |
5626: 100 Ω (± 1 Ω) |
Resistance Ratio W(Ga) |
W(302.9146K) ≥ 1.11807 |
Calibrated Accuracy†(k=2) |
± 0.006 °C at –200 °C |
Stability |
5626: ± 0.003 °C |
Long-Term Drift (k=2) |
5626: < 0.006 °C/100 hours at 661 °C |
Immersion |
At least 12.7 cm (5 in) recommended |
Sheath |
Inconel™ 600 |
Lead Wires |
4-wire Super-Flex PVC, 22 AGW |
Termination |
Gold-plated spade lugs, or specify |
Size |
6.35 mm dia. x 305 mm, 381 mm, or 508 mm (0.25 x 12, 15, or 20 in) standard, custom lengths available |
Calibration |
Accredited calibrations from Fluke Calibration |
†Includes calibration and 100 hr drift |
Accessory | Description |
---|---|
2609 |
Probe Carrying Case, Plastic (for probes 635 mm [25 in] in length) |
Product Manuals |
---|
Application Notes |
---|
Application Notes |
---|
Papers / Articles |
---|
I Just Got My Probe Recalibrated, Now What? |
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
(item no. 3055440)
PRODUCT OVERVIEW
High-temperature secondary standards
- Range to 661°C
- Meets all ITS-90 requirements for resistance ratios
- Rtp drift < 20 mK after 500 hours at 661°C
- Calibrated accuracy of ± 0.006 °C at 0 °C
Fluke Calibration's high-temp secondary standards fill the gap between affordable, but temperature-limited secondary PRTs (platinum resistance thermometers) and more expensive, highly accurate SPRTs (standard platinum resistance thermometers).
If you’re using block calibrators, furnaces, or temperature points above normal PRT (platinum resistance thermometer) temperatures (420 °C), then these two PRTs are for you. The Fluke 5626 is nominally 100 Ω and the 5628 (formerly Hart Scientific) is nominally 25.5 Ω. Both instruments have a temperature range of –200 °C to 661 °C. They make great working or check standards for calibration work up to the aluminum point.
Using a regular PRT at temperatures above 500 °C exposes the platinum to contamination. If the PRT is used as a reference or calibration standard, contamination is a major problem. SPRTs (standard platinum resistance thermometers), which are more expensive and delicate, can handle the higher temperatures, but with greater risk to the instrument due to shock, contamination, or mishandling. The 5626 and 5628 are designed to reduce the contamination risk through the use of internal protection while not impairing performance.
In addition to the right measurement performance and durability, a PRT for secondary applications should be priced affordably. Fluke Calibration’s new PRTs are inexpensive and come with an accredited calibration. The calibration comes complete with ITS-90 constants and a resistance-versus-temperature table.
Check the temperature range, check the stability, check the price! Who else gives you this much quality, performance, and value for your money? No one!
SPECIFICATIONS
Temperature Range |
–200 °C to 661 °C |
Handle Temp. |
0 °C to 80 °C |
RTPW |
5626: 100 Ω (± 1 Ω) |
Resistance Ratio W(Ga) |
W(302.9146K) ≥ 1.11807 |
Calibrated Accuracy†(k=2) |
± 0.006 °C at –200 °C |
Stability |
5626: ± 0.003 °C |
Long-Term Drift (k=2) |
5626: < 0.006 °C/100 hours at 661 °C |
Immersion |
At least 12.7 cm (5 in) recommended |
Sheath |
Inconel™ 600 |
Lead Wires |
4-wire Super-Flex PVC, 22 AGW |
Termination |
Gold-plated spade lugs, or specify |
Size |
6.35 mm dia. x 305 mm, 381 mm, or 508 mm (0.25 x 12, 15, or 20 in) standard, custom lengths available |
Calibration |
Accredited calibrations from Fluke Calibration |
†Includes calibration and 100 hr drift |
Accessory | Description |
---|---|
2609 |
Probe Carrying Case, Plastic (for probes 635 mm [25 in] in length) |
Product Manuals |
---|
Application Notes |
---|
Application Notes |
---|
Papers / Articles |
---|
I Just Got My Probe Recalibrated, Now What? |
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.