Fluke 1529 Chub-E4 Standards Thermometer

SKU: 1671710
£4,544.00

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

Part Number

Checkout Secure
Need more info? Call us +61 8 9335 1718

1529 Chub-E4 Standards Thermometer Lab-quality accuracy

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

 (item no. 1671710, 1671722, 1671731)

Lab-quality accuracy on four channels for PRTs, thermistors and thermocouples

  • Four channels for PRTs, thermistors, and thermocouples
  • Displays eight user-selected data fields from any channel
  • Logs up to 8,000 readings with date and time stamps
  • Battery provides eight hours of continuous operation

So you need multiple channels, battery power, outstanding accuracy, and the ability to read many different sensor types—but you don’t need all the power of a 1 ppm Super-Thermometer. We have the answer for you.

Fluke Calibration’s 1529 Chub-E4 Thermometer gives you four channels, three major sensor types, lab-quality accuracy, and a ton of great features, all at a price you’ll love. 

FEATURES

The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways according to your preference. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem.

100-ohm, 25-ohm, or 10-ohm PRTs and RTDs are read using ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods. Typical accuracies include ±0.004 °C at –100 °C and ±0.009 °C at 100 °C. Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025 °C at 25 °C with resolution of 0.0001 °.

Thermocouple inputs read all the common thermocouple types, including B, E, J, K, N, R, S, T, and Au-Pt, and allow you to choose between internal and external reference junction compensation. Typical accuracy for a type J thermocouple at 600 °C is ±0.35 °C using internal reference junction compensation and not including the thermocouple. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples.)

PRTs and thermistors connect easily to the 1529 using Fluke Calibration’s patented mini DWF connectors, which accept bare wire, spade lug, or mini banana plug terminations. Thermocouples connect using standard or miniature terminations. Measurements are taken each second and can be taken simultaneously or sequentially. A special high-speed mode allows measurements on one channel to be taken at the rate of 10 per second.

Display

If you think three sensor types and four inputs sounds versatile, wait until you see the display panel on the Chub-E4. Displaying measurements in °C, °F, K, ohms, or millivolts and choosing temperature resolution from 0.01 to 0.0001 are just the beginning.

You can also select any eight items from our long list of displayable data fields to view on-screen. Choose statistical functions such as averages, standard deviations, and spreads; choose probe information such as probe type and serial number; choose T1–T2 functions using inputs from any two channels; or choose utility functions such as the date, time, and battery power level. You can even save up to 10 screen configurations for easy recall.

The push of a single front-panel button also brings up a simple menu system to easily guide you through all the internal setup and memory options of the 1529. Probe coefficients, sample intervals, communication settings, password settings, and a host of other functions are all easily accessible.

Communications

The memory and communications capabilities of the Chub-E4 make it perfect for benchtop thermometry, on-site measurements, lab calibration work, and remote data logging. Optional software packages from Fluke make this one of the most powerful thermometers on the market.

With battery power and memory to store up to 8,000 measurements (including date and time stamps) at user-selected intervals, the 1529 has plenty of data logging capability. Store 100 individual measurements or any number of automatic log sessions (up to 8,000 readings), each tagged with an identifying session label. Fourteen different logging intervals may be selected, from 0.1 second to 60 minutes.

With Fluke Calibration’s 9935 LogWare II (page 85), data may be quickly downloaded to your PC for complete graphical and statistical analysis. Separate log sessions may even be automatically downloaded to separate files based on session labels. With this software, the 1529 can even be used for real-time data logging. Log four channels at once directly to your PC with virtually no limit to the number of data points you take. You can analyze data, set alarm events, and even set delayed start and stop times.

With MET/TEMP II software, the Chub-E4 may be integrated into a completely automated calibration system. Use one input for your reference thermometer and calibrate up to three other thermometers automatically (see page 81). An RS-232 port is standard on every unit. An IEEE-488 port is optional.

More great features

Did we forget some aspect of versatility on this thermometer? No!

The 1529 runs on AC power from 100 to 240 volts, DC power from 12 to 16 volts, or off its internal nickel-metal-hydride battery for eight hours between charging. The standard battery charges in less than three hours and lasts through 500 charge/recharge cycles.

If you want to rack-mount your Chub-E4, we’ve even got a rack-mount kit for you. This unit fits on your benchtop, in your instrument rack, and even in your hand.

Of course, all the reference thermometers you might need for your 1529 are available from Fluke, including secondary standard PRTs, standard thermistors, and noble-metal thermocouples. Carrying cases and even a serial printer for direct printer output are also available.

We’ve said it before and we’ll keep saying it: Fluke Calibration simply makes the best thermometer readouts in the world. No one else gives you a comparable combination of accuracy, versatility, productivity-enhancing features, and price. No one. Get a Chub-E4 and just enjoy everything it’ll do for you. You’ll love it.

  

SPECIFICATIONS

  PRT / RTD Thermistor  Thermocouple 
Inputs  2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples from www.flukecal.com.) 
Temperature Range  –189 °C to 960 °C  –50 °C to 150 °C  –270 °C to 1800 °C 
Measurement Range  0 to 400 Ω 0 to 500 KΩ –10 to 100 mV 
Characterizations  ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen  Steinhart-Hart, YSI-400  NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial 
Temperature Accuracy (meter only)  ± 0.004 °C at –100 °C 
± 0.006 °C at 0 °C 
± 0.009 °C at 100 °C 
± 0.012 °C at 200 °C 
± 0.018 °C at 400 °C 
± 0.024 °C at 600 °C 
± 0.0025 °C at 0 °C 
± 0.0025 °C at 25 °C 
± 0.004 °C at 50 °C 
± 0.010 °C at 75 °C 
± 0.025 °C at 100 °C 

 

                    Ext. RJC     Int. RJC 
B at 1000 °C  ± 0.6 °C  ± 0.6 °C
E at 600 °C  ± 0.07 °C  ± 0.25 °C
J at 600 °C  ± 0.1 °C  ± 0.35 °C
K at 600 °C  ± 0.15 °C  ± 0.4 °C
N at 600 °C  ± 0.15 °C  ± 0.3 °C
R at 1000 °C  ± 0.4 °C  ± 0.5 °C
S at 1000 °C  ± 0.5 °C  ± 0.6 °C
T at 200 °C  ± 0.1 °C  ± 0.3 °C
Temperature Resolution  0.001 °  0.0001 °  0.01 to 0.001 ° 
Resistance/Voltage Accuracy  0 Ω to 20 Ω:  ± 0.0005Ω 
20 Ω to 400 Ω:  ± 25 ppm of rdg. 
0 Ω to 5 KΩ:  ± 0.5 Ω 
5 KΩ to 200 KΩ:  ± 100 ppm of rdg. 
200 KΩ to 500 KΩ  ± 300 ppm of rdg. 
–10 to 50 mV:  ± 0.005 mV 
50 to 100 mV:  ± 100 ppm of rdg. 
Internal RJC: ± 0.25 °C) 
Operating Range  16 °C to 30 °C 
Measurement Interval  0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval 
Excitation Current  1 mA, reversing  2 and 10 µA, automatically selected  n/a 
Display  33 x 127 mm (1.3 x 5 in) backlit LCD graphical display 
Display Units  °C,  °F, K, Ω, KΩ, mV 
Data Logging  Up to 8,000 time- and date-stamped measurements can be logged 
Logging Intervals  0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes 
Averaging  Moving average of most recent 2 to 10 readings, user selectable 
Probe Connection  Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations  Universal receptacle accepts miniature and standard TC connectors 
Communications  RS-232 included, IEEE-488 (GPIB) optional 
AC Power  100–240 V ac, 50-60 Hz, 0.4 A 
DC Power  12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) 
Battery  NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles 
Size (HxWxD)  102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) 
Weight  2 kg (4.5 lb) 
Calibration  Accredited resistance and voltage calibrations are provided.

 

Model Name Description
1529

Chub-E4 Thermometer, 2 TC and 2 PRT/Thermistor inputs

1529-R

Chub-E4 Thermometer, 4 PRT/Thermistor inputs

1529-T

Chub-E4 Thermometer, 4 TC inputs

Accessories common to all models:

Accessory Description
2362

Spare AC Adapter, 15 V

9322

Rugged Carrying Case, holds 1529 and four probes up to 12

2513-1529

Rack-Mount Kit

2506-1529

IEEE Option

1929-2

System Verification, PRT with Readout, Accredited.
Choose two temperature points, extra points at additional cost. Available temperature points are –197 °C, -80 °C , –39 °C, 0.01°C, 30 °C, 157 °C, 232 °C, 300 °C, 420 °C, 500 °C, 660 °C.

1929-5

System Verification, Thermistor with Readout, Accredited.
Choose two temperature points; extra points at additional cost. Available temperature points are -30 °C, -20 °C, -10 °C, 0 °C, 10 °C, 20 °C, 30 °C, 40 °C, 50 °C, 60 °C, 70 °C, 80 °C, 90 °C, 100 °C.

1930

System Calibration, PRT with Readout, Accredited.
Choose PRT temperature range for the calibration. Available temperature ranges are –200 °C to 500 °C, –200 °C to 420 °C, –80 °C to 420 °C, –40 °C to 420 °C, –40 °C to 232 °C, 0 °C to 420 °C.

1935

System Calibration, Thermistor with Readout, NVLAP-accredited
Choose thermistor temperature range for the calibration. Available temperature ranges are 100 °C span (6 points over span), 60 °C span (7 points over span), 100 °C span (11 points over span).

9935-S

Software, LogWare II, Single User

9938

MET/TEMP II Software

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

 

Product Manuals
application/pdf icon 1529 Chub-E4 Thermometer Readout Technical Guide (1.21 MB)
application/pdf icon 1529 Statement Memory of Volatility (15.41 KB)
application/pdf icon 1529 测温仪用户手册 (1.33 MB)
application/pdf icon 1529 测温仪说明书 (1.27 MB)
Application Notes
application/pdf icon Calculating Calibration Uncertainties in an Automated Temperature Calibration System (426.88 KB)
application/pdf icon Establishment of a Secondary Temperature Calibration Laboratory (3.09 MB)
application/pdf icon Industrial temperature readout and probe selection guide (2.33 MB)
application/pdf icon Anleitung zur Auswahl von Temperaturanzeigegeräten und Messfühlern für den Industrieeinsatz (German) (585.2 KB)
application/pdf icon Guide de sélection des afficheurs et sondes de températures industrielles (French) (584.47 KB)
application/pdf icon Guía para la elección de sonda y lectura de temperatura industrial (Spanish) (581.27 KB)
application/pdf icon Руководство по выбору промышленных показаний и зонда температуры (Russian) (686.56 KB)
application/pdf icon Guia de seleção de instrumento de leitura e sonda de temperatura industrial (Portuguese) (580.6 KB)
application/pdf icon 工业测温仪和探头选型指南 (Chinese) (253.92 KB)
application/pdf icon Probe-to-Readout Adapter Guide (943.12 KB)
application/pdf icon Temperature Calibration Equipment: A Technician's Guide (1.62 MB)
application/pdf icon Temperature measurement and calibration: What every instrument technician should know (1.65 MB)
application/pdf icon Temperaturmessung und -kalibrierung (German) (650.54 KB)
application/pdf icon Mesure et étalonnage thermique (French) (655.57 KB)
application/pdf icon Medición y calibración de temperatura (Spanish) (651.42 KB)
application/pdf icon English: Thermocouple App Notes Series, 1 of 4 - Thermocouple Fundamentals (2.5 MB)
application/pdf icon Korean: 열전대 응용시리즈 첫번째 - 열전대의 기본사항 (2.28 MB)
application/pdf icon German: Thermocouple App Notes Series, 1 of 4 - Grundlagen zu Thermoelementen (2.22 MB)
application/pdf icon French: Thermocouple App Notes
Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

1529 Chub-E4 Standards Thermometer Lab-quality accuracy

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

 (item no. 1671710, 1671722, 1671731)

Lab-quality accuracy on four channels for PRTs, thermistors and thermocouples

  • Four channels for PRTs, thermistors, and thermocouples
  • Displays eight user-selected data fields from any channel
  • Logs up to 8,000 readings with date and time stamps
  • Battery provides eight hours of continuous operation

So you need multiple channels, battery power, outstanding accuracy, and the ability to read many different sensor types—but you don’t need all the power of a 1 ppm Super-Thermometer. We have the answer for you.

Fluke Calibration’s 1529 Chub-E4 Thermometer gives you four channels, three major sensor types, lab-quality accuracy, and a ton of great features, all at a price you’ll love. 

FEATURES

The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways according to your preference. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem.

100-ohm, 25-ohm, or 10-ohm PRTs and RTDs are read using ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods. Typical accuracies include ±0.004 °C at –100 °C and ±0.009 °C at 100 °C. Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025 °C at 25 °C with resolution of 0.0001 °.

Thermocouple inputs read all the common thermocouple types, including B, E, J, K, N, R, S, T, and Au-Pt, and allow you to choose between internal and external reference junction compensation. Typical accuracy for a type J thermocouple at 600 °C is ±0.35 °C using internal reference junction compensation and not including the thermocouple. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples.)

PRTs and thermistors connect easily to the 1529 using Fluke Calibration’s patented mini DWF connectors, which accept bare wire, spade lug, or mini banana plug terminations. Thermocouples connect using standard or miniature terminations. Measurements are taken each second and can be taken simultaneously or sequentially. A special high-speed mode allows measurements on one channel to be taken at the rate of 10 per second.

Display

If you think three sensor types and four inputs sounds versatile, wait until you see the display panel on the Chub-E4. Displaying measurements in °C, °F, K, ohms, or millivolts and choosing temperature resolution from 0.01 to 0.0001 are just the beginning.

You can also select any eight items from our long list of displayable data fields to view on-screen. Choose statistical functions such as averages, standard deviations, and spreads; choose probe information such as probe type and serial number; choose T1–T2 functions using inputs from any two channels; or choose utility functions such as the date, time, and battery power level. You can even save up to 10 screen configurations for easy recall.

The push of a single front-panel button also brings up a simple menu system to easily guide you through all the internal setup and memory options of the 1529. Probe coefficients, sample intervals, communication settings, password settings, and a host of other functions are all easily accessible.

Communications

The memory and communications capabilities of the Chub-E4 make it perfect for benchtop thermometry, on-site measurements, lab calibration work, and remote data logging. Optional software packages from Fluke make this one of the most powerful thermometers on the market.

With battery power and memory to store up to 8,000 measurements (including date and time stamps) at user-selected intervals, the 1529 has plenty of data logging capability. Store 100 individual measurements or any number of automatic log sessions (up to 8,000 readings), each tagged with an identifying session label. Fourteen different logging intervals may be selected, from 0.1 second to 60 minutes.

With Fluke Calibration’s 9935 LogWare II (page 85), data may be quickly downloaded to your PC for complete graphical and statistical analysis. Separate log sessions may even be automatically downloaded to separate files based on session labels. With this software, the 1529 can even be used for real-time data logging. Log four channels at once directly to your PC with virtually no limit to the number of data points you take. You can analyze data, set alarm events, and even set delayed start and stop times.

With MET/TEMP II software, the Chub-E4 may be integrated into a completely automated calibration system. Use one input for your reference thermometer and calibrate up to three other thermometers automatically (see page 81). An RS-232 port is standard on every unit. An IEEE-488 port is optional.

More great features

Did we forget some aspect of versatility on this thermometer? No!

The 1529 runs on AC power from 100 to 240 volts, DC power from 12 to 16 volts, or off its internal nickel-metal-hydride battery for eight hours between charging. The standard battery charges in less than three hours and lasts through 500 charge/recharge cycles.

If you want to rack-mount your Chub-E4, we’ve even got a rack-mount kit for you. This unit fits on your benchtop, in your instrument rack, and even in your hand.

Of course, all the reference thermometers you might need for your 1529 are available from Fluke, including secondary standard PRTs, standard thermistors, and noble-metal thermocouples. Carrying cases and even a serial printer for direct printer output are also available.

We’ve said it before and we’ll keep saying it: Fluke Calibration simply makes the best thermometer readouts in the world. No one else gives you a comparable combination of accuracy, versatility, productivity-enhancing features, and price. No one. Get a Chub-E4 and just enjoy everything it’ll do for you. You’ll love it.

  

SPECIFICATIONS

  PRT / RTD Thermistor  Thermocouple 
Inputs  2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering;
PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. Download the application note Using Fluke Calibration Readouts with Tungsten-Rhenium and other Thermocouples from www.flukecal.com.) 
Temperature Range  –189 °C to 960 °C  –50 °C to 150 °C  –270 °C to 1800 °C 
Measurement Range  0 to 400 Ω 0 to 500 KΩ –10 to 100 mV 
Characterizations  ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen  Steinhart-Hart, YSI-400  NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial 
Temperature Accuracy (meter only)  ± 0.004 °C at –100 °C 
± 0.006 °C at 0 °C 
± 0.009 °C at 100 °C 
± 0.012 °C at 200 °C 
± 0.018 °C at 400 °C 
± 0.024 °C at 600 °C 
± 0.0025 °C at 0 °C 
± 0.0025 °C at 25 °C 
± 0.004 °C at 50 °C 
± 0.010 °C at 75 °C 
± 0.025 °C at 100 °C 

 

                    Ext. RJC     Int. RJC 
B at 1000 °C  ± 0.6 °C  ± 0.6 °C
E at 600 °C  ± 0.07 °C  ± 0.25 °C
J at 600 °C  ± 0.1 °C  ± 0.35 °C
K at 600 °C  ± 0.15 °C  ± 0.4 °C
N at 600 °C  ± 0.15 °C  ± 0.3 °C
R at 1000 °C  ± 0.4 °C  ± 0.5 °C
S at 1000 °C  ± 0.5 °C  ± 0.6 °C
T at 200 °C  ± 0.1 °C  ± 0.3 °C
Temperature Resolution  0.001 °  0.0001 °  0.01 to 0.001 ° 
Resistance/Voltage Accuracy  0 Ω to 20 Ω:  ± 0.0005Ω 
20 Ω to 400 Ω:  ± 25 ppm of rdg. 
0 Ω to 5 KΩ:  ± 0.5 Ω 
5 KΩ to 200 KΩ:  ± 100 ppm of rdg. 
200 KΩ to 500 KΩ  ± 300 ppm of rdg. 
–10 to 50 mV:  ± 0.005 mV 
50 to 100 mV:  ± 100 ppm of rdg. 
Internal RJC: ± 0.25 °C) 
Operating Range  16 °C to 30 °C 
Measurement Interval  0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval 
Excitation Current  1 mA, reversing  2 and 10 µA, automatically selected  n/a 
Display  33 x 127 mm (1.3 x 5 in) backlit LCD graphical display 
Display Units  °C,  °F, K, Ω, KΩ, mV 
Data Logging  Up to 8,000 time- and date-stamped measurements can be logged 
Logging Intervals  0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes 
Averaging  Moving average of most recent 2 to 10 readings, user selectable 
Probe Connection  Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations  Universal receptacle accepts miniature and standard TC connectors 
Communications  RS-232 included, IEEE-488 (GPIB) optional 
AC Power  100–240 V ac, 50-60 Hz, 0.4 A 
DC Power  12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) 
Battery  NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles 
Size (HxWxD)  102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) 
Weight  2 kg (4.5 lb) 
Calibration  Accredited resistance and voltage calibrations are provided.

 

Model Name Description
1529

Chub-E4 Thermometer, 2 TC and 2 PRT/Thermistor inputs

1529-R

Chub-E4 Thermometer, 4 PRT/Thermistor inputs

1529-T

Chub-E4 Thermometer, 4 TC inputs

Accessories common to all models:

Accessory Description
2362

Spare AC Adapter, 15 V

9322

Rugged Carrying Case, holds 1529 and four probes up to 12

2513-1529

Rack-Mount Kit

2506-1529

IEEE Option

1929-2

System Verification, PRT with Readout, Accredited.
Choose two temperature points, extra points at additional cost. Available temperature points are –197 °C, -80 °C , –39 °C, 0.01°C, 30 °C, 157 °C, 232 °C, 300 °C, 420 °C, 500 °C, 660 °C.

1929-5

System Verification, Thermistor with Readout, Accredited.
Choose two temperature points; extra points at additional cost. Available temperature points are -30 °C, -20 °C, -10 °C, 0 °C, 10 °C, 20 °C, 30 °C, 40 °C, 50 °C, 60 °C, 70 °C, 80 °C, 90 °C, 100 °C.

1930

System Calibration, PRT with Readout, Accredited.
Choose PRT temperature range for the calibration. Available temperature ranges are –200 °C to 500 °C, –200 °C to 420 °C, –80 °C to 420 °C, –40 °C to 420 °C, –40 °C to 232 °C, 0 °C to 420 °C.

1935

System Calibration, Thermistor with Readout, NVLAP-accredited
Choose thermistor temperature range for the calibration. Available temperature ranges are 100 °C span (6 points over span), 60 °C span (7 points over span), 100 °C span (11 points over span).

9935-S

Software, LogWare II, Single User

9938

MET/TEMP II Software

Priority Gold Instrument CarePlan

Fluke Calibration Priority Gold Instrument CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

Silver CarePlan

Fluke Calibration Silver CarePlans are available for most calibration products. Please contact your local Fluke Calibration sales representative for details or to request a quote. You may also call the Customer Care Center at 877-355-3225 or send email to careplans@flukecal.com.

 

Product Manuals
application/pdf icon 1529 Chub-E4 Thermometer Readout Technical Guide (1.21 MB)
application/pdf icon 1529 Statement Memory of Volatility (15.41 KB)
application/pdf icon 1529 测温仪用户手册 (1.33 MB)
application/pdf icon 1529 测温仪说明书 (1.27 MB)
Application Notes
application/pdf icon Calculating Calibration Uncertainties in an Automated Temperature Calibration System (426.88 KB)
application/pdf icon Establishment of a Secondary Temperature Calibration Laboratory (3.09 MB)
application/pdf icon Industrial temperature readout and probe selection guide (2.33 MB)
application/pdf icon Anleitung zur Auswahl von Temperaturanzeigegeräten und Messfühlern für den Industrieeinsatz (German) (585.2 KB)
application/pdf icon Guide de sélection des afficheurs et sondes de températures industrielles (French) (584.47 KB)
application/pdf icon Guía para la elección de sonda y lectura de temperatura industrial (Spanish) (581.27 KB)
application/pdf icon Руководство по выбору промышленных показаний и зонда температуры (Russian) (686.56 KB)
application/pdf icon Guia de seleção de instrumento de leitura e sonda de temperatura industrial (Portuguese) (580.6 KB)
application/pdf icon 工业测温仪和探头选型指南 (Chinese) (253.92 KB)
application/pdf icon Probe-to-Readout Adapter Guide (943.12 KB)
application/pdf icon Temperature Calibration Equipment: A Technician's Guide (1.62 MB)
application/pdf icon Temperature measurement and calibration: What every instrument technician should know (1.65 MB)
application/pdf icon Temperaturmessung und -kalibrierung (German) (650.54 KB)
application/pdf icon Mesure et étalonnage thermique (French) (655.57 KB)
application/pdf icon Medición y calibración de temperatura (Spanish) (651.42 KB)
application/pdf icon English: Thermocouple App Notes Series, 1 of 4 - Thermocouple Fundamentals (2.5 MB)
application/pdf icon Korean: 열전대 응용시리즈 첫번째 - 열전대의 기본사항 (2.28 MB)
application/pdf icon German: Thermocouple App Notes Series, 1 of 4 - Grundlagen zu Thermoelementen (2.22 MB)
application/pdf icon French: Thermocouple App Notes

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

6 Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.
Fluke 1529 Chub-E4 Standards Thermometer

Fluke 1529 Chub-E4 Standards Thermometer

£4,544.00

Part Number

Fluke 1529 Chub-E4 Standards Thermometer

Fluke 1529 Chub-E4 Standards Thermometer

£4,544.00

Part Number

Recently viewed products