Your Cart ()
cload

GUARANTEED SAFE & SECURE CHECKOUT

FREE Shipping For Purchases Over $250 within Australia

Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with i400 Current Clamp FC Kit

SKU: 4692725
£1,056.00
Checkout Secure
Need more info? Call us +61 8 9335 1718

(item no. 4692725)

Features

Includes the Fluke 1587 FC 2-in-1 Insulation DMM and the Fluke i400 Current Clamp

  • With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
  • Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit

The Fluke 1587 FC 2-in1 Insulation DMM

  • Pl/DAR measurements with TrendIt™ graphs
  • Memory storage through Fluke Connect Measurements app
  • Temperature Compensation through Fluke Connect Measurements app
  • VFD low-pass filter for accurate motor drive measurements
  • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
  • Insulation test voltages 500 V, 1000 V
  • Insulation test: 0.01 M? to 2.0 G?
  • Insulation test: 0.1 M? to 600 M?
  • Auto-discharge of capacitive voltage
  • Insulation test smoothing reading
  • Frequency / Capacitance / Diode test / Temperature
  • Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
  • Resistance (0.1 ? to 50 M?) / Continuity / Auto power off
  • Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case

Fluke i400 AC Current Clamp

  • Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
  • 1 mA/Amp output guarantees easy reading
  • CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
  • Specially designed to offer maximum utility in a very compact shape
  • Maximum conductor: Ø 32 mm
  • 1 year warranty

Product overview: Fluke 1587/i400 Current Clamp FC Kit

The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:

  • Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
  • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
  • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
  • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

The Fluke i400 AC CurrentClamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

Specifications: Fluke 1587/i400 Current Clamp FC Kit

Fluke 1587 FC Insulation Multimeter

Electrical Specifications
AC voltage measurement
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
¹ 1 kHz bandwidth
Low-Pass Filter Voltage 
Range
600.0 mV Resolution 0.1 mV
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
6.000 V Resolution 0.001 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
60.00 V Resolution 0.01 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
600.0 V Resolution 0.1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
1000 V Resolution 1 V
Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
DC Voltage Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
6.000 V dc 0.001 V ±(0.09% + 2)
60.00 V dc 0.01 V ±(0.09% + 2)
600.0 V dc 0.1 V ±(0.09% + 2)
1000 V dc 1 V ±(0.09% + 2)
Input impedance  10 MΩ (nominal), <100 pF
Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz
Common mode rejection ratio  >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
Accuracies apply to ± 100% of range
DC Millivolts Measurement
Range Resolution Accuracy ±(% of Rdg + Counts)
600.0 mVdc 0.1 mV ±(0.1% + 1)
DC and AC Current Measurement
AC 45 Hz to 1000 Hz
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
Range 60 mA 
Resolution 0.01 mA 
Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
Burden voltage (Typical) 2 mV/mA
DC
Range 400 mA
Resolution 0.1 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Range 60 mA
Resolution 0.01 mA
Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
Burden voltage (Typical) 2 mV/mA
Overload 600 mA for 2 minutes maximum
Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
¹ 1 kHz bandwidth
Ohms Measurement
Range Resolution Accuracy +(% of Rdg+Counts)¹
600.0 Ω 0.1 Ω ±(0.9% + 2)
6.000 kΩ 0.001 kΩ ±(0.9% + 2)
60.00 kΩ 0.01 kΩ ±(0.9% + 2)
600.0 kΩ 0.1 KΩ ±(0.9% + 2)
6.000 MΩ 0.001 MΩ ±(0.9% + 2)
50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
Overload protection  1000 V rms or dc
Open circuit test voltage  <8.0 V dc
Short circuit current  <1.1 mA
¹ Accuracies apply from 0% to 100% of range
² Up to 80% relative humidity
Diode Test
Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
Accuracy ±(2% + 3)
Continuity Test
Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
Open circuit voltage <8.0 V
Short circuit current 1.0 mA typical
Overload protection 1000 V rms
Response time >1 m sec
Frequency Measurement
Range Resolution Accuracy ±(% of Rdg+Counts)
99.99 Hz  0.01 Hz  ±(0.1% + 1)
999.9 Hz  0.1 Hz  ±(0.1% + 1)
9.999 kHz  0.001 kHz  ±(0.1% + 1)
99.99 kHz  0.01 kHz  ±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 mV 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV 
DC Trigger Levels¹ to 20 kHz² NA
6.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  1.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V 
DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
60.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  10.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V 
DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
600.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
1000.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  300.0 V 
V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
² Usable to 100 kHz with full scale input
Capacitance
Range  Resolution  Accuracy ±(% of Rdg+Counts)
1000 nF  1 nF ±(1.2% + 2)
10.00 μF  0.01 μF ±(1.2% + 2)
100.0 μF  0.1 μF ±(1.2% ±90 counts)
9999 μF  1 μF ±(1.2% ±90 counts)
Temperature Measurement
Range  Resolution  Accuracy ±(% of Rdg+Counts)¹
-40 ° C to 537 ° C  0.1 °C  ±(1% + 10 counts)
-40 ° F to 998 ° F  0.1 °F  ±(1% + 18 counts)
¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Measurement range 0.01 MΩ to 2 GΩ
Test voltages 50, 100, 250, 500, 1000 V
Test voltage accuracy +20%, -0%
Short-circuit test current 1 mA nominal
Auto discharge Discharge time <0.5 second for C = 1 μF or less
Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive load Operable with up to 1 μF load
Output Voltage
50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 50.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 50 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
Resolution 0.01 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 6.0 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
Display range 60 to 100 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 100 kΩ
Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
250 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
Resolution 0.1 MΩ
Test current 1 mA @ 250 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 250 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 250 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
Resolution 0.1 MΩ
Test current 1 mA @ 500 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 500 MΩ
Resolution 1 MΩ
Test current 1 mA @ 500 kΩ 
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
Resolution 0.1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 60 to 600 MΩ 
Resolution 1 MΩ
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
Display range 0.6 to 2.0 GΩ 
Resolution 100 MΩ 
Test current 1 mA @ 1 MΩ
Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
General Specifications
Maximum voltage applied to any terminal and common 1000 V
Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
Relative humidity Noncondensing
0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Radio frequency communication 2.4 GHz ISM Band
Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
Electromagnetic Compatibility 
International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Enclosure protection IEC 60529: IP40 (non-operating)
Safety
IEC 61010-1 Pollution Degree 2
IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
Batteries  Four AA batteries (NEDA 15A or IEC LR6)
Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight 550 g (1.2 lb)
Altitude Operating 2000 m
Storage 12,000 m
Over-range capability 110% of range except for capacitance which is 100%
Frequency overload protection <107 V Hz
Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

Fluke i400 AC Current Clamp

Specifications
Nominal current range 400  A
Continuous current range 1 A - 400 A
Maximum non-destructive current 1000 A
Lowest measurable current 1 A
Basic accuracy 2% + 0.06 A
(45-400 Hz)
(% reading + floorspec)
Useable frequency 5 Hz - 20 kHz
Output level(s) 1 mA/A
Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty 1 year
Maximum conductor diameter 32 mm (1.25 in)
Maximum conductor size (busbar) 750 MCM
Output cable length 1.5 m (59 in)
Shrouded banana plugs Yes

 

Includes:

    • Fluke 1587 FC 2-in-1 Insulation DMM
    • Fluke i400 Current Clamp

       Manuals

      Data Sheets

      Shipping This Item Ships from Fremantle, Perth, Western Australia
      Please allow 2 - 10 days for your order to arrive.

      Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

      Returns are easy.

      simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

      Description

      (item no. 4692725)

      Features

      Includes the Fluke 1587 FC 2-in-1 Insulation DMM and the Fluke i400 Current Clamp

      • With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
      • Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit

      The Fluke 1587 FC 2-in1 Insulation DMM

      • Pl/DAR measurements with TrendIt™ graphs
      • Memory storage through Fluke Connect Measurements app
      • Temperature Compensation through Fluke Connect Measurements app
      • VFD low-pass filter for accurate motor drive measurements
      • Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
      • Insulation test voltages 500 V, 1000 V
      • Insulation test: 0.01 M? to 2.0 G?
      • Insulation test: 0.1 M? to 600 M?
      • Auto-discharge of capacitive voltage
      • Insulation test smoothing reading
      • Frequency / Capacitance / Diode test / Temperature
      • Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
      • Resistance (0.1 ? to 50 M?) / Continuity / Auto power off
      • Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case

      Fluke i400 AC Current Clamp

      • Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
      • 1 mA/Amp output guarantees easy reading
      • CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
      • Specially designed to offer maximum utility in a very compact shape
      • Maximum conductor: Ø 32 mm
      • 1 year warranty

      Product overview: Fluke 1587/i400 Current Clamp FC Kit

      The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:

      • Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
      • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
      • Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
      • Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

      The Fluke i400 AC CurrentClamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

      Specifications: Fluke 1587/i400 Current Clamp FC Kit

      Fluke 1587 FC Insulation Multimeter

      Electrical Specifications
      AC voltage measurement
      Range
      600.0 mV Resolution 0.1 mV
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
      6.000 V Resolution 0.001 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
      60.00 V Resolution 0.01 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
      600.0 V Resolution 0.1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
      1000 V Resolution 1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
      ¹ 1 kHz bandwidth
      Low-Pass Filter Voltage 
      Range
      600.0 mV Resolution 0.1 mV
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
      6.000 V Resolution 0.001 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
      60.00 V Resolution 0.01 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
      600.0 V Resolution 0.1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
      1000 V Resolution 1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% - 3)
      DC Voltage Measurement
      Range Resolution Accuracy ±(% of Rdg + Counts)
      6.000 V dc 0.001 V ±(0.09% + 2)
      60.00 V dc 0.01 V ±(0.09% + 2)
      600.0 V dc 0.1 V ±(0.09% + 2)
      1000 V dc 1 V ±(0.09% + 2)
      Input impedance  10 MΩ (nominal), <100 pF
      Normal mode rejection ratio  >60 dB @ 50 Hz or 60 Hz
      Common mode rejection ratio  >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
      Accuracies apply to ± 100% of range
      DC Millivolts Measurement
      Range Resolution Accuracy ±(% of Rdg + Counts)
      600.0 mVdc 0.1 mV ±(0.1% + 1)
      DC and AC Current Measurement
      AC 45 Hz to 1000 Hz
      Range 400 mA
      Resolution 0.1 mA
      Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
      Burden voltage (Typical) 2 mV/mA
      Range 60 mA 
      Resolution 0.01 mA 
      Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
      Burden voltage (Typical) 2 mV/mA
      DC
      Range 400 mA
      Resolution 0.1 mA
      Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
      Burden voltage (Typical) 2 mV/mA
      Range 60 mA
      Resolution 0.01 mA
      Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
      Burden voltage (Typical) 2 mV/mA
      Overload 600 mA for 2 minutes maximum
      Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
      AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
      Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
      ¹ 1 kHz bandwidth
      Ohms Measurement
      Range Resolution Accuracy +(% of Rdg+Counts)¹
      600.0 Ω 0.1 Ω ±(0.9% + 2)
      6.000 kΩ 0.001 kΩ ±(0.9% + 2)
      60.00 kΩ 0.01 kΩ ±(0.9% + 2)
      600.0 kΩ 0.1 KΩ ±(0.9% + 2)
      6.000 MΩ 0.001 MΩ ±(0.9% + 2)
      50.0 MΩ ² 0.01 MΩ ±(1.5% + 3)
      Overload protection  1000 V rms or dc
      Open circuit test voltage  <8.0 V dc
      Short circuit current  <1.1 mA
      ¹ Accuracies apply from 0% to 100% of range
      ² Up to 80% relative humidity
      Diode Test
      Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
      Accuracy ±(2% + 3)
      Continuity Test
      Continuity indication Continuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
      Open circuit voltage <8.0 V
      Short circuit current 1.0 mA typical
      Overload protection 1000 V rms
      Response time >1 m sec
      Frequency Measurement
      Range Resolution Accuracy ±(% of Rdg+Counts)
      99.99 Hz  0.01 Hz  ±(0.1% + 1)
      999.9 Hz  0.1 Hz  ±(0.1% + 1)
      9.999 kHz  0.001 kHz  ±(0.1% + 1)
      99.99 kHz  0.01 kHz  ±(0.1% + 1)
      Frequency Counter Sensitivity
      600.0 mV ac  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 mV 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 150.0 mV 
      DC Trigger Levels¹ to 20 kHz² NA
      6.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  1.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 1.5 V 
      DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
      60.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  10.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz 36.0 V 
      DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
      600.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  100.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
      DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
      1000.0 V  V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz  300.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz -
      DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
      ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
      ² Usable to 100 kHz with full scale input
      Capacitance
      Range  Resolution  Accuracy ±(% of Rdg+Counts)
      1000 nF  1 nF ±(1.2% + 2)
      10.00 μF  0.01 μF ±(1.2% + 2)
      100.0 μF  0.1 μF ±(1.2% ±90 counts)
      9999 μF  1 μF ±(1.2% ±90 counts)
      Temperature Measurement
      Range  Resolution  Accuracy ±(% of Rdg+Counts)¹
      -40 ° C to 537 ° C  0.1 °C  ±(1% + 10 counts)
      -40 ° F to 998 ° F  0.1 °F  ±(1% + 18 counts)
      ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
      Insulation Specifications
      Measurement range 0.01 MΩ to 2 GΩ
      Test voltages 50, 100, 250, 500, 1000 V
      Test voltage accuracy +20%, -0%
      Short-circuit test current 1 mA nominal
      Auto discharge Discharge time <0.5 second for C = 1 μF or less
      Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
      Maximum capacitive load Operable with up to 1 μF load
      Output Voltage
      50 V (0% to +20%) Display range 0.01 to 6.00 MΩ
      Resolution 0.01 MΩ
      Test current 1 mA @ 50 kΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
      Display range 6.0 to 50.0 MΩ
      Resolution 0.1 MΩ
      Test current 1 mA @ 50 kΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
      100 V (0% to +20%) Display range 0.01 to 6.00 MΩ
      Resolution 0.01 MΩ
      Test current 1 mA @ 100 kΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
      Display range 6.0 to 60.0 MΩ
      Resolution 0.1 MΩ
      Test current 1 mA @ 100 kΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
      Display range 60 to 100 MΩ 
      Resolution 1 MΩ
      Test current 1 mA @ 100 kΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
      250 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
      Resolution 0.1 MΩ
      Test current 1 mA @ 250 kΩ 
      Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
      Display range 60 to 250 MΩ 
      Resolution 1 MΩ
      Test current 1 mA @ 250 kΩ 
      Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
      500 V (0% to +20%) Display range 0.1 to 60.0 MΩ
      Resolution 0.1 MΩ
      Test current 1 mA @ 500 kΩ 
      Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
      Display range 60 to 500 MΩ
      Resolution 1 MΩ
      Test current 1 mA @ 500 kΩ 
      Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
      1000 V (0% to +20%) Display range 0.1 to 60.0 MΩ 
      Resolution 0.1 MΩ
      Test current 1 mA @ 1 MΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
      Display range 60 to 600 MΩ 
      Resolution 1 MΩ
      Test current 1 mA @ 1 MΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
      Display range 0.6 to 2.0 GΩ 
      Resolution 100 MΩ 
      Test current 1 mA @ 1 MΩ
      Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
      General Specifications
      Maximum voltage applied to any terminal and common 1000 V
      Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
      Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
      Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
      Relative humidity Noncondensing
      0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
      0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
      0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
      Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
      Radio frequency communication 2.4 GHz ISM Band
      Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
      Electromagnetic Compatibility 
      International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
      Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
      Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
      Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
      Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
      Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
      USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
      Enclosure protection IEC 60529: IP40 (non-operating)
      Safety
      IEC 61010-1 Pollution Degree 2
      IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
      Batteries  Four AA batteries (NEDA 15A or IEC LR6)
      Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
      Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
      Weight 550 g (1.2 lb)
      Altitude Operating 2000 m
      Storage 12,000 m
      Over-range capability 110% of range except for capacitance which is 100%
      Frequency overload protection <107 V Hz
      Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

      Fluke i400 AC Current Clamp

      Specifications
      Nominal current range 400  A
      Continuous current range 1 A - 400 A
      Maximum non-destructive current 1000 A
      Lowest measurable current 1 A
      Basic accuracy 2% + 0.06 A
      (45-400 Hz)
      (% reading + floorspec)
      Useable frequency 5 Hz - 20 kHz
      Output level(s) 1 mA/A
      Safety Specifications
      Safety CAT IV 600 V, CAT III, 1000 V
      Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010
      Mechanical and General Specifications
      Warranty 1 year
      Maximum conductor diameter 32 mm (1.25 in)
      Maximum conductor size (busbar) 750 MCM
      Output cable length 1.5 m (59 in)
      Shrouded banana plugs Yes

       

      Includes:

        • Fluke 1587 FC 2-in-1 Insulation DMM
        • Fluke i400 Current Clamp

           Manuals

          Data Sheets

          Shipping

          Shipping This item ships to

          Delivery & Returns

          Please allow 2 - 10 days for your order to arrive.

          Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

          Returns are easy.

          simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

          Reviews

          6 Great reasons to buy from us:

          • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

            30 Days Return

            If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
          • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

            Returns are Easy

            Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
          • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

            Best Price Guarantee

            In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
          • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

            We guarantee your satisfaction

            We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
          • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

            100% Safe & Secure

            Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
          • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

            Best Laser Warranties in the Business

            Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.
          Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with i400 Current Clamp FC Kit

          Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with i400 Current Clamp FC Kit

          £1,056.00
          Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with i400 Current Clamp FC Kit

          Fluke 1587/I400 FC 2-in-1 Insulation Multimeter with i400 Current Clamp FC Kit

          £1,056.00

          Recently viewed products