Features
- Versatile, three-phase Fluke Connect-compatible power logger for conducting basic energy and power quality studies
- Automatically captures and logs voltage, current, power, harmonics and associated power quality values.
- Provides the highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
- Automatically logs all measured values and stores more than 20 separate logging sessions
Product overview: Fluke 1736 Three-Phase Energy Logger
More visibility, reduced uncertainty and better power quality and energy consumption decisions
The Fluke 1736 Three-Phase Power Logger built with Fluke Connect® mobile app and desktop software compatibility gives you the data you need to make critical power quality and energy decisions in real-time. The best test tool for conducting energy studies and basic power quality logging, the 1736 automatically captures and logs over 500 power quality parameters so you have more visibility into the data you need to optimise system reliability and savings.
An optimised user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Fluke Energy Analyse Plus software package.
The Fluke 1736 is the best general purpose power logger. If you're looking for a power logger with the same great energy study capabilities and more advanced power quality logging capabilities, the Fluke 1738 is the ideal choice.
Specifications: Fluke 1736 Three-Phase Energy Logger
Specifications | |||||
Accuracy | |||||
Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ||
Voltage | 1000 V | 0.1 V | ±(0.2% + 0.01%) | ||
Current: Direct input | i17xx-flex 1500 12" | 150 A | 0.1 A | ±(1% + 0.02%) | |
1500 A | 1 A | ±(1% + 0.02%) | |||
i17xx-flex 3000 24" | 300 A | 1 A | ±(1% + 0.03%) | ||
3000 A | 10 A | ±(1% + 0.03%) | |||
i17xx-flex 6000 36" | 600 A | 1 A | ±(1.5% + 0.03%) | ||
6000 A | 10 A | ±(1.5% + 0.03%) | |||
i40s-EL clamp | 4 A | 1 mA | ±(0.7% + 0.02%) | ||
40 A | 10 mA | ±(0.7% + 0.02%) | |||
Frequency | 42.5 Hz to 69 Hz | 0.01 Hz | ±(0.1%) | ||
Auxillary input | ±10 V dc | 0.1 mV | ±(0.2% + 0.02%) | ||
Voltage min/max | 1000 V | 0.1 V | ±(1% + 0.1%) | ||
Current min/max | Defined by accessory | Defined by accessory | ±(5% + 0.2%) | ||
THD on voltage | 1000% | 0.1% | ±0.5 | ||
THD on current | 1000% | 0.1% | ±0.5 | ||
Voltage harmonics 2nd to 50th | 1000 V | 0.1 V | ≥ 10 V: ±5% of reading | ||
< 10 V: ±0.5V | |||||
Current harmonics 2nd to 50th | Defined by accessory | Defined by accessory | ≥ 3% of current range: ±5% of reading | ||
< 3% of current range: ±0.15% of range | |||||
Unbalance | 100% | 0.1% | ±0.2 | ||
Intrinsic Uncertainty ±(% of reading +% of range)¹ | |||||
Parameter | Influence quantity | iFlex1500-12 | iFlex3000-24 | iFlex6000-36 | i40S-EL |
150 A / 1500 A | 300 A / 3000 A | 600 A / 6000 A | 4 A / 40 A | ||
Active Power P | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Active Energy Ea | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent power S | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent Energy Eap | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Reactive power Q | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
Reactive Energy Er | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
Power Factor PF | - | ±0.025 | |||
Displacement Power Factor | - | ±0.025 | |||
DBF/cosϕ | - | ±0.025 | |||
Additional uncertainty in% of range¹ | VP-N>250 V | 0.015% | 0.0225% | 0.0225% | 0.015% |
¹Range = 1000 V x Irange Reference conditions:
|
Electrical Specifications | |||
Power Supply | |||
Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit | ||
100 V to 240 V using standard power cord (IEC 60320 C7) | |||
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) | ||
Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) | ||
Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input | ||
Mains power frequency | 50/60 Hz ±15% | ||
Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable | ||
On-battery runtime | Four hours in standard operating mode, up to 5.5 hours in power saving mode | ||
Charging time | < 6 hours | ||
Data Acquisition | |||
Resolution | 16-bit synchronous sampling | ||
Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency | ||
Input signal frequency | 50/60 Hz (42.5 to 69 Hz) | ||
Circuit types | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies) | ||
Data storage | Internal flash memory (not user replaceable) | ||
Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹ | ||
¹The number of possible logging sessions and logging period depends on user requirements. | |||
Basic Interval | |||
Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy | ||
Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min | ||
Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms | ||
Demand Interval (Energy Meter Mode) | |||
Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy | ||
Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off | ||
Power Quality Measurements | |||
Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD | ||
Averaging interval | 10 min | ||
Individual harmonics | 2nd to 50th harmonic | ||
Total harmonic distortion | Calculated on 50 harmonics | ||
Events | Voltage: dips, swells, interruptions, current: inrush current | ||
Triggered recordings | Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30) | ||
Waveform of voltage and current | |||
Standards Compliance | |||
Harmonics | IEC 61000-4-7: Class 1 | ||
IEEE 519 (short time harmonics) | |||
Power quality | IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device) | ||
Power | IEEE 1459 | ||
Power quality compliance | EN50160 (for measured parameters) | ||
Interfaces | |||
USB-A | File transfer via USB flash drive, firmware updates Max. current: 120 mA |
||
WiFi | File transfer and remote control via direct connection or WiFi infrastructure | ||
Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738 or 1736 upgrade option) | ||
USB-mini | Data download device to PC | ||
Voltage Inputs | |||
Number of inputs | 4 (3 phases and neutral) | ||
Maximum input voltage | 1000 Vrms, CF 1.7 | ||
Input impedance | 10 MΩ | ||
Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz | ||
Scaling | 1:1 and variable | ||
Measurement category | 1000 V CAT III/600 V CAT IV | ||
Current Inputs | |||
Number of inputs | 4, mode selected automatically for attached sensor | ||
Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 | ||
Rogowski coil input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range | ||
Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12" | ||
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24" | |||
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36" | |||
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |||
Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz | ||
Scaling | 1:1 and variable | ||
Auxiliary Inputs | |||
Number of inputs | 2 | ||
Input range | 0 to ±10 V dc, 1reading/s | ||
Scale factor (available 2014) | Format: mx + b (gain and offset) user configurable | ||
Displayed units (available 2014) | User configurable (7 characters, for example, °C, psi, or m/s) | ||
Wireless Connection | |||
Number of inputs | 2 | ||
Supported modules | Fluke Connect® 3000 series | ||
Acquisition | 1 reading/s | ||
Environmental Specifications | |||
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) | ||
Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) | ||
Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH | ||
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH | |||
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH | |||
Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) | ||
Storage altitude | 12,000m | ||
Enclosure | IP50 in accordance with EN60529 | ||
Vibration | MIL-T-28800E, Type 3, Class III, Style B | ||
Safety | IEC 61010-1 | ||
IEC Mains Input: Overvoltage Category II, Pollution Degree 2 | |||
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 | |||
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |||
Electromagnetic compatibility | EN 61326-1: Industrial CISPR 11: Group 1, Class A | ||
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |||
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |||
Temperature coefficient | 0.1 x accuracy specification/°C | ||
General Specifications | |||
Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel | ||
Warranty | Instrument and power supply: Two-years (battery not included) | ||
Accessories: one-year | |||
Calibration cycle: two-years | |||
Dimensions | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) | ||
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) | |||
Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) | |||
Weight | Instrument: 1.1 kg (2.5 lb) | ||
Power supply: 400 g (0.9 lb) | |||
Tamper protection | Kensington lock slot | ||
i17xx-flex 1500 12" Flexible Current Probe Specifications | |||
Measuring range | 1 to 150 A ac/10 to 1500 A ac | ||
Nondestructive current | 100 kA (50/60 Hz) | ||
Intrinsic error at reference condition* | ±0.7% of reading | ||
Accuracy 173x + iFlex | ±(1% of reading + 0.02% of range) | ||
Temperature coefficient over operating temperature range | 0.05% of reading/°C 0.09% of reading/°F | ||
Working voltage | 1000 V CAT III, 600 V CAT IV | ||
Probe cable length | 305 mm (12 in) | ||
Probe cable diameter | 7.5 mm (0.3 in) | ||
Minimum bending radius | 38 mm (1.5 in) | ||
Output cable length | 2 m (6.6 ft) | ||
Weight | 115 g | ||
Probe cable material | TPR | ||
Coupling material | POM + ABS/PC | ||
Output cable | TPR/PVC | ||
Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) | ||
Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) | ||
Relative humidity, operating | 15% to 85% non-condensing | ||
IP rating | IEC 60529:IP50 | ||
Warranty | One-year | ||
* Reference condition:
|
Manuals
- 1736/1738 | Users manual
- 1736/1738 | Users manual supplement
- USB1 FC | Users manual
- 1732, 1734, 1736, 1738 | Statement of memory volatility
- 1732/1734/1736/1738 3540 FC | Calibration manual
- 1736/1738 | Safety sheet
- 1736/1738 | Quick reference guide
- Auxiliary Input Adapter for the 17xx | Instruction sheet
- Auxiliary Input Adapter for the 17xx | Instruction sheet supplement
- MP1 Magnet Probe | Instruction sheet
- Test Lead Set | Fluke Industrial Group
Data Sheets
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
(item no. 4534519)
Features
- Versatile, three-phase Fluke Connect-compatible power logger for conducting basic energy and power quality studies
- Automatically captures and logs voltage, current, power, harmonics and associated power quality values.
- Provides the highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
- Automatically logs all measured values and stores more than 20 separate logging sessions
Product overview: Fluke 1736 Three-Phase Energy Logger
More visibility, reduced uncertainty and better power quality and energy consumption decisions
The Fluke 1736 Three-Phase Power Logger built with Fluke Connect® mobile app and desktop software compatibility gives you the data you need to make critical power quality and energy decisions in real-time. The best test tool for conducting energy studies and basic power quality logging, the 1736 automatically captures and logs over 500 power quality parameters so you have more visibility into the data you need to optimise system reliability and savings.
An optimised user interface, flexible current probes, and an intelligent measurement verification function that allows you to reduce measurement errors by digitally verifying and correcting common connection errors makes setup easier than ever and reduces measurement uncertainty. Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins. You can also quickly and easily chart and graph measurements to help identify issues and create detailed reports with the included Fluke Energy Analyse Plus software package.
The Fluke 1736 is the best general purpose power logger. If you're looking for a power logger with the same great energy study capabilities and more advanced power quality logging capabilities, the Fluke 1738 is the ideal choice.
Specifications: Fluke 1736 Three-Phase Energy Logger
Specifications | |||||
Accuracy | |||||
Parameter | Range | Resolution | Intrinsic Accuracy at Reference Conditions (% of Reading +% of Full Scale) | ||
Voltage | 1000 V | 0.1 V | ±(0.2% + 0.01%) | ||
Current: Direct input | i17xx-flex 1500 12" | 150 A | 0.1 A | ±(1% + 0.02%) | |
1500 A | 1 A | ±(1% + 0.02%) | |||
i17xx-flex 3000 24" | 300 A | 1 A | ±(1% + 0.03%) | ||
3000 A | 10 A | ±(1% + 0.03%) | |||
i17xx-flex 6000 36" | 600 A | 1 A | ±(1.5% + 0.03%) | ||
6000 A | 10 A | ±(1.5% + 0.03%) | |||
i40s-EL clamp | 4 A | 1 mA | ±(0.7% + 0.02%) | ||
40 A | 10 mA | ±(0.7% + 0.02%) | |||
Frequency | 42.5 Hz to 69 Hz | 0.01 Hz | ±(0.1%) | ||
Auxillary input | ±10 V dc | 0.1 mV | ±(0.2% + 0.02%) | ||
Voltage min/max | 1000 V | 0.1 V | ±(1% + 0.1%) | ||
Current min/max | Defined by accessory | Defined by accessory | ±(5% + 0.2%) | ||
THD on voltage | 1000% | 0.1% | ±0.5 | ||
THD on current | 1000% | 0.1% | ±0.5 | ||
Voltage harmonics 2nd to 50th | 1000 V | 0.1 V | ≥ 10 V: ±5% of reading | ||
< 10 V: ±0.5V | |||||
Current harmonics 2nd to 50th | Defined by accessory | Defined by accessory | ≥ 3% of current range: ±5% of reading | ||
< 3% of current range: ±0.15% of range | |||||
Unbalance | 100% | 0.1% | ±0.2 | ||
Intrinsic Uncertainty ±(% of reading +% of range)¹ | |||||
Parameter | Influence quantity | iFlex1500-12 | iFlex3000-24 | iFlex6000-36 | i40S-EL |
150 A / 1500 A | 300 A / 3000 A | 600 A / 6000 A | 4 A / 40 A | ||
Active Power P | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Active Energy Ea | PF ≥ 0.99 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent power S | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Apparent Energy Eap | 0 ≤ PF ≤ 1 | 1.2% + 0.005% | 1.2% + 0.0075% | 1.7% + 0.0075% | 1.2% + 0.005% |
Reactive power Q | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
Reactive Energy Er | 0 ≤ PF ≤ 1 | 2.5% of measured apparent power | |||
Power Factor PF | - | ±0.025 | |||
Displacement Power Factor | - | ±0.025 | |||
DBF/cosϕ | - | ±0.025 | |||
Additional uncertainty in% of range¹ | VP-N>250 V | 0.015% | 0.0225% | 0.0225% | 0.015% |
¹Range = 1000 V x Irange Reference conditions:
|
Electrical Specifications | |||
Power Supply | |||
Voltage range | 100 V to 500 V using safety plug input when powering from the measurement circuit | ||
100 V to 240 V using standard power cord (IEC 60320 C7) | |||
Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) | ||
Efficiency | ≥ 68.2% (in accordance with energy efficiency regulations) | ||
Maximum no-load consumption | < 0.3 W only when powered using IEC 60320 input | ||
Mains power frequency | 50/60 Hz ±15% | ||
Battery | Li-ion 3.7 V, 9.25 Wh, customer-replaceable | ||
On-battery runtime | Four hours in standard operating mode, up to 5.5 hours in power saving mode | ||
Charging time | < 6 hours | ||
Data Acquisition | |||
Resolution | 16-bit synchronous sampling | ||
Sampling frequency | 10.24 kHz at 50/60 Hz, synchronized to mains frequency | ||
Input signal frequency | 50/60 Hz (42.5 to 69 Hz) | ||
Circuit types | 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies) | ||
Data storage | Internal flash memory (not user replaceable) | ||
Memory size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events¹ | ||
¹The number of possible logging sessions and logging period depends on user requirements. | |||
Basic Interval | |||
Measured parameters | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy | ||
Averaging interval | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min | ||
Averaging time min/max values | Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms | ||
Demand Interval (Energy Meter Mode) | |||
Measured parameters | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy | ||
Interval | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off | ||
Power Quality Measurements | |||
Measured parameter | Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD | ||
Averaging interval | 10 min | ||
Individual harmonics | 2nd to 50th harmonic | ||
Total harmonic distortion | Calculated on 50 harmonics | ||
Events | Voltage: dips, swells, interruptions, current: inrush current | ||
Triggered recordings | Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000-4-30) | ||
Waveform of voltage and current | |||
Standards Compliance | |||
Harmonics | IEC 61000-4-7: Class 1 | ||
IEEE 519 (short time harmonics) | |||
Power quality | IEC 61000-4-30 Class S, IEC62586-1 (PQI-S device) | ||
Power | IEEE 1459 | ||
Power quality compliance | EN50160 (for measured parameters) | ||
Interfaces | |||
USB-A | File transfer via USB flash drive, firmware updates Max. current: 120 mA |
||
WiFi | File transfer and remote control via direct connection or WiFi infrastructure | ||
Bluetooth | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1738 or 1736 upgrade option) | ||
USB-mini | Data download device to PC | ||
Voltage Inputs | |||
Number of inputs | 4 (3 phases and neutral) | ||
Maximum input voltage | 1000 Vrms, CF 1.7 | ||
Input impedance | 10 MΩ | ||
Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz | ||
Scaling | 1:1 and variable | ||
Measurement category | 1000 V CAT III/600 V CAT IV | ||
Current Inputs | |||
Number of inputs | 4, mode selected automatically for attached sensor | ||
Input voltage | Clamp input: 500 mVrms/50 mVrms; CF 2.8 | ||
Rogowski coil input | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range | ||
Range | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12" | ||
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24" | |||
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36" | |||
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL | |||
Bandwidth (-3 dB) | 42.5 Hz - 3.5 kHz | ||
Scaling | 1:1 and variable | ||
Auxiliary Inputs | |||
Number of inputs | 2 | ||
Input range | 0 to ±10 V dc, 1reading/s | ||
Scale factor (available 2014) | Format: mx + b (gain and offset) user configurable | ||
Displayed units (available 2014) | User configurable (7 characters, for example, °C, psi, or m/s) | ||
Wireless Connection | |||
Number of inputs | 2 | ||
Supported modules | Fluke Connect® 3000 series | ||
Acquisition | 1 reading/s | ||
Environmental Specifications | |||
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) | ||
Storage temperature | -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) | ||
Operating humidity | 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH | ||
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH | |||
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH | |||
Operating altitude | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) | ||
Storage altitude | 12,000m | ||
Enclosure | IP50 in accordance with EN60529 | ||
Vibration | MIL-T-28800E, Type 3, Class III, Style B | ||
Safety | IEC 61010-1 | ||
IEC Mains Input: Overvoltage Category II, Pollution Degree 2 | |||
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2 | |||
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V | |||
Electromagnetic compatibility | EN 61326-1: Industrial CISPR 11: Group 1, Class A | ||
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment) | |||
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | |||
Temperature coefficient | 0.1 x accuracy specification/°C | ||
General Specifications | |||
Color LCD display | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel | ||
Warranty | Instrument and power supply: Two-years (battery not included) | ||
Accessories: one-year | |||
Calibration cycle: two-years | |||
Dimensions | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) | ||
Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) | |||
Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) | |||
Weight | Instrument: 1.1 kg (2.5 lb) | ||
Power supply: 400 g (0.9 lb) | |||
Tamper protection | Kensington lock slot | ||
i17xx-flex 1500 12" Flexible Current Probe Specifications | |||
Measuring range | 1 to 150 A ac/10 to 1500 A ac | ||
Nondestructive current | 100 kA (50/60 Hz) | ||
Intrinsic error at reference condition* | ±0.7% of reading | ||
Accuracy 173x + iFlex | ±(1% of reading + 0.02% of range) | ||
Temperature coefficient over operating temperature range | 0.05% of reading/°C 0.09% of reading/°F | ||
Working voltage | 1000 V CAT III, 600 V CAT IV | ||
Probe cable length | 305 mm (12 in) | ||
Probe cable diameter | 7.5 mm (0.3 in) | ||
Minimum bending radius | 38 mm (1.5 in) | ||
Output cable length | 2 m (6.6 ft) | ||
Weight | 115 g | ||
Probe cable material | TPR | ||
Coupling material | POM + ABS/PC | ||
Output cable | TPR/PVC | ||
Operating temperature | -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F) | ||
Temperature, non-operating | -40 °C to +80 °C (-40 °F to 176 °F) | ||
Relative humidity, operating | 15% to 85% non-condensing | ||
IP rating | IEC 60529:IP50 | ||
Warranty | One-year | ||
* Reference condition:
|
Manuals
- 1736/1738 | Users manual
- 1736/1738 | Users manual supplement
- USB1 FC | Users manual
- 1732, 1734, 1736, 1738 | Statement of memory volatility
- 1732/1734/1736/1738 3540 FC | Calibration manual
- 1736/1738 | Safety sheet
- 1736/1738 | Quick reference guide
- Auxiliary Input Adapter for the 17xx | Instruction sheet
- Auxiliary Input Adapter for the 17xx | Instruction sheet supplement
- MP1 Magnet Probe | Instruction sheet
- Test Lead Set | Fluke Industrial Group
Data Sheets
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.