(item no. 1281139)
Product overview
The Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.
Features
- Dual-input digital thermometer for lab, QA, process calibration, food safety and HVAC
- Shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display
- Features fast response and laboratory accuracy (0.05% + 0.3°C)
- Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
Other useful features:
- Easy-to-access battery door that allows replacing the battery without breaking the calibration seal
- Comes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty
- Powered by three, standard AA batteries -30-
- Features an electronic offset function that compensates for thermocouple errors to maximize overall accuracy
- Measures J, K, T, and E-type thermocouples
- Handles temperatures up to 900°C (1600°F)
- Presents results in °C, °F, or Kelvin (K)
- Provides a user-friendly front panel that is easy to set up and operate
- Offers sleep mode to increase battery life; 1000-hour battery life typical
- Offers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation
Specifications:
Specifications | ||
Temperature accuracy | Above -100°C | J, K, T, E, and N-type: ±[0.05% + 0.3°C]1 |
R and S-type: ±[0.05% + 0.4°C]1 | ||
Below -100°C | J, K, E, and N-types: ±[0.20% + 0.3°C]1 | |
T-type: ±[0.50% + 0.3°C] | ||
Temperature | J-type | -210°C to 1200°C |
K-type | -200°C to 1372°C | |
T-type | -250°C to 400°C | |
E-type | -150°C to 1000°C | |
N-type | -200°C to 1300°C1 | |
R and S-type | 0°C to 1767°C1 | |
Temperature scale | ITS-90 | |
Applicable standards | NIST-175 | |
Display resolution | 0.1°C, 0.1 K < 1000 | |
1°C, 1 K ≥ 1000 | ||
1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples. | ||
Environmental Specifications | ||
Operating temperature | -10°C to 50°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 0% to 90%; 0°C to 35°C | |
0% to 70%; 0°C to 50°C | ||
Safety Specifications | ||
Overvoltage category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 | |
Agency approvals | CE, CSA, TÜV (pending) | |
Mechanical and General Specifications | ||
Size (L x W x D) | 173 x 86 x 38 mm | |
Weight | 400 g | |
Batteries | 3 AA batteries; typical 1000-hour life |
Models:
Resources:
Manuals
- 51 & 52 Series II | Users manual
- 53 & 54 Series II | Users manual
- 53IIB/54IIB | Users manual
- 51, 52, 50S and 50D | Statement of memory volatility
- 51, 52, 53, 54 (and Series II and Series IIB) | Statement of memory volatility
- 51-54 Series II | Product overview
- 51-54 Series II | Service manual
- 51-54 Series II | Service manual supplement
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
(item no. 1281139)
Product overview
The Fluke 52 II dual-input digital thermometer delivers fast response with laboratory accuracy (0.05% + 0.3°C). You can use the 52 II to measure two contact temperature inputs simultaneously on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or E-type thermocouple temperature sensors. The user friendly-front panel and large, backlit display make it easy to view results from both inputs in multiple ways. And the sleep mode feature preserves battery life to give you a typical thousand hours of operation.
Features
- Dual-input digital thermometer for lab, QA, process calibration, food safety and HVAC
- Shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display
- Features fast response and laboratory accuracy (0.05% + 0.3°C)
- Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
Other useful features:
- Easy-to-access battery door that allows replacing the battery without breaking the calibration seal
- Comes with splash- and dust-resistant case protected by an impact-absorbing holster and a three-year warranty
- Powered by three, standard AA batteries -30-
- Features an electronic offset function that compensates for thermocouple errors to maximize overall accuracy
- Measures J, K, T, and E-type thermocouples
- Handles temperatures up to 900°C (1600°F)
- Presents results in °C, °F, or Kelvin (K)
- Provides a user-friendly front panel that is easy to set up and operate
- Offers sleep mode to increase battery life; 1000-hour battery life typical
- Offers optional ToolPak accessory to hang the thermometer from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation
Specifications:
Specifications | ||
Temperature accuracy | Above -100°C | J, K, T, E, and N-type: ±[0.05% + 0.3°C]1 |
R and S-type: ±[0.05% + 0.4°C]1 | ||
Below -100°C | J, K, E, and N-types: ±[0.20% + 0.3°C]1 | |
T-type: ±[0.50% + 0.3°C] | ||
Temperature | J-type | -210°C to 1200°C |
K-type | -200°C to 1372°C | |
T-type | -250°C to 400°C | |
E-type | -150°C to 1000°C | |
N-type | -200°C to 1300°C1 | |
R and S-type | 0°C to 1767°C1 | |
Temperature scale | ITS-90 | |
Applicable standards | NIST-175 | |
Display resolution | 0.1°C, 0.1 K < 1000 | |
1°C, 1 K ≥ 1000 | ||
1. Only the Fluke Models 53 II B and 54 II Bthermometers are capable of measuring N, R, and S-type thermocouples. | ||
Environmental Specifications | ||
Operating temperature | -10°C to 50°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 0% to 90%; 0°C to 35°C | |
0% to 70%; 0°C to 50°C | ||
Safety Specifications | ||
Overvoltage category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 | |
Agency approvals | CE, CSA, TÜV (pending) | |
Mechanical and General Specifications | ||
Size (L x W x D) | 173 x 86 x 38 mm | |
Weight | 400 g | |
Batteries | 3 AA batteries; typical 1000-hour life |
Models:
Resources:
Manuals
- 51 & 52 Series II | Users manual
- 53 & 54 Series II | Users manual
- 53IIB/54IIB | Users manual
- 51, 52, 50S and 50D | Statement of memory volatility
- 51, 52, 53, 54 (and Series II and Series IIB) | Statement of memory volatility
- 51-54 Series II | Product overview
- 51-54 Series II | Service manual
- 51-54 Series II | Service manual supplement
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.