Product Overview
Combines the functions of a clamp meter, oscilloscope, data logger, and digital power meter in one, making this unit ideal for measurements on switching loads such as variable frequency drives, electronic lighting, and UPS systems. Also, it's Hall Effect measurement system measures DC currents without breaking the circuit.
One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, colour display to analyse the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyser ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.
Features
- AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
- Highest safety rating: 600 V CAT IV power analyser is rated for use at the service entrance
- Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
- Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
- Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
- Troubleshoot harmonics: Analyse and log harmonics digitally or graphically
- Inrush current: Capture and analyse nuisance tripping, from 3 seconds to 300 seconds
- Easy to use: Easily confirm power meter setup with large backlit colour display of waveforms and trends
- USB download: Download logged data with PowerLog application software to view trends and screenshots, analyse and create reports simply.
- Battery eliminator: powers the instrument when performing extended logging sessions.
- 3-Phase power: Built in capability for balanced loads
- View graphs and generate reports: Use power analyser with included Power Log software
Besides effectively performing basic tasks like measuring wattage, the Fluke 345 power meters offer the ease of use, portability and flexibility needed to resolve most power issues in commercial, industrial and residential settings.
Applications
- Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
- Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
- Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
- Load studies - Verify electrical system capacity before adding loads
Specifications
Current Measurement | |
Measuring Range | 0 to 2000 A DC or 1400 AC RMS |
Autorange Facility | 40 A/400 A/2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 in 2000 A range |
Accuracy | |
DC and DC RMS | I > 10 A: ±1.5% rdg ±5 digits I < 10 A: ±0.2 A |
AVG | I > 10 A: ±3% rdg ±5 digits I < 10 A: ±0.5 A |
Pk | I > 10 A: ±5% rdg ±5 digits I < 10 A: ±0.5 A |
AHr | I > 10 A: ±2% rdg ±5 digits I < 10 A: ±0.5 AHr |
CF (Crest Factor) | 1.1 ≤ CF < 3: ±3% rdg ±5 digits 3 ≤ CF < 5: ±5% rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2% ≤ RPL < 100%: ±3% rdg ±5 digits 100% ≤ RPL < 600%: ±5% rdg ± 5 digits Resolution: 0.01% |
Voltage Measurement | |
Measuring Range | 0 to 825 V DC or AC RMS |
Autorange Facility | 4 V/40 V/400 V/750 V |
Resolution | 1 mV in 4 V range 10 mV in 40 V range 100 mV in 400 V range 1 V in 750 V range |
DC and DC RMS | V > 1 V: ±1% rdg ±5 digits V < 1 V: ± 0.02 V |
AVG | V > 1 V: ±3% rdg ±5 digits V < 1 V: ± 0.03 V |
Pk | V > 1 V: ±5% rdg ±5 digits V < 1 V: ± 0.03 V |
CF (Crest Factor) | V > 1 V: ±5% rdg ±5 digits V < 1 V: ±5% rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2% ≤ RPL < 100%: ±3% rdg ± 5 digits 100% ≤ RPL < 600%: ±5% rdg ± 5 digits Resolution: 0.1% |
Harmonics | |
THD (Total Harmonic Distortion) | 1% ≤ THD < 100%: ±3% rdg ± 5 digits 100% ≤ THD < 600%: ±5% rdg ± 5 digits Resolution: 0.1% |
DF (Distortion Factor) | 1% ≤ DF < 100%: ±3% rdg ± 5 digits Resolution: 0.1% H02 ≤ Vharm < H13: ±5% rdg ± 2 digits H13 ≤ Vharm ≤ H30: ± 10% rdg ± 2 digits |
Watts Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1650 kW DC or 1200 kW AC |
Autoranging Facility | 4, 40, 400, 1650 kW AC |
Resolution | 1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW |
Accuracy | 2.5% rdg ± 5 digits W1ø <2 kW ± 0.08 kW W3ø <4 kW ± 0.25 kW |
VA Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1650 kVA DC or 1200 kVA AC |
Autorange Facility | 4, 40, 400, 1650 kVA |
Resolution | 1 VA in 4 kVA 10 VA in 40 kVA 100 VA in 400 kVA 1 kVA in 1200 kVA |
Accuracy | VA >2 kVA: 2.5% rdg ± 5 digits VA <2 kVA: ±0.08 kVA |
VAR Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1250 kVAR |
Autorange Facility | 4, 40, 400, 1200 kVAR |
Resolution | 1 VAR in 4 kVAR 10 VAR in 40 kVAR 100 VAR in 400 kVAR 1 kVAR in 1200 kVAR |
Accuracy | VA >4 kVAR: 2.5% rdg ± 5 digits VA <4 kVAR: ±0.25 kVAR |
Power Factor Range | 0.3 >PF <0.99 |
Power Factor (Single - and Three-Phase) | |
Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ±3° |
Frequency Range | 15 Hz to 1 kHz |
Displacement Power Factor | |
Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ±3° |
Frequency Range | 15 to 22 Hz and 45 to 65 Hz |
Kilowatt Hour (kWHr) | |
Measuring Range | 40,000 kWHr |
Autorange Facility | 1, 40, 400, 4000, 40,000 kWHr |
Resolution | 1 WHr in 4 kWHr 10 WHr in 40 kWHr 100 WHr in 400 kWHr 1 kWHr in 4,000 kWHr 10 kWHr in 40,000 kWHr |
Accuracy | kWHr >2 kWHr: ±3% ± 5 digits kWHr <2 kWHr: ±0.08 kWHr |
All Watts /VA /VAR /PF Measurements | Frequency range: DC and 15 Hz to 1 kHz Current range: 10 to 1400 A RMS Voltage range: 1 to 825 V RMS Maximum input: 825 V RMS/1400 A RMS Maximum overload: 1000 V RMS/10,000 A |
Frequency Measurement | |
Measuring Range | 15 Hz to 1 kHz |
Resolution | 0.1 Hz |
Accuracy | 15 to 22 Hz ± 0.5% rdg 40 to 70 Hz ± 0.5% rdg 15 to 1000 Hz ± 1% rdg |
Current Range | 10 to 1400 A RMS |
Voltage Range | 1 to 825 V RMS |
Current Measurement | |
Ranges | 10/20/40/100/200/400/1000/2000 A |
Resolution | 1 A in 40 A 10 A in 400 A 50 A in 2000 A |
Accuracy | ±3% rdg ± 1 pixel |
Maximum Overload | 10,000 A |
Voltage Measurement | |
Ranges | 4/10/20/40/100/200/400/1000 V |
Resolution | 100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
Accuracy | ±2% rdg ± 1 pixel |
Maximum Overload | 1000 V RMS |
Frequency Range | DC and 15 to 600 Hz |
Time Base | 2.5, 5, 10, 25, 50 ms/div |
Refresh Rate | 0.5 seconds |
Maximum Sampling Rate | 15.625 kHz |
Inrush Current Function | |
Ranges | 40, 400, and 2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy | I > 10 A: ±5% rdg ± 1 pixel I < 10 A: ±0.5 A |
Maximum Overload | Maximum overload 10,000 A or RMS x frequency <400,000 |
Capture Time | 1, 3, 10, 30, 100, and 300 s |
Maximum Sampling Rate | 15.625 kHz |
Logging Memory | |
Logging Areas | Three areas that can be used individually or combined into one large area |
Averaging Periods | 1, 2, 5, 10, 30 s, 1, 5, 10, 15 min, and custom |
General Specifications | |
Display | Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
Power Supply | Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
Battery Life Typically | >10 hours (backlight on full) >12 hours (backlight reduced) |
Battery Eliminator BE345 | Input: 110/230 V, 50/60 Hz Output: 15 V DC, 300 mA |
Reference Conditions | All accuracies stated at 73.4 ± 1.8°F (23 ± 1°C) |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Temperature Coefficient of Current | ≤± 0.15% of rdg per °C |
Temperature Coefficient of Voltage | ≤± 0.15% of rdg per °C |
Maximum Relative Humidity | 80 % for temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F (40°C) |
Maximum Operating Altitude | 6561.7' (2000 m) |
Mechanical | |
Cleaning | The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
Jaw Capacity | 2.3" (58 mm) diameter |
Jaw Opening | 2.4" (60 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm |
Weight | 1.8 lbs (820 g) batteries included |
Electrical Safety | |
Maximum Safe Working Voltages | Current measurement: 600 V AC RMS or DC between uninsulated conductor and ground Voltage measurement: 600 V AC RMS or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
EMC | |
Emission | IEC/EN 61326-1:1997 class B |
Immunity | IEC/EN 61326-1:1997 |
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
DISCONTINUED ITEM. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 2584181)
Product Overview
Combines the functions of a clamp meter, oscilloscope, data logger, and digital power meter in one, making this unit ideal for measurements on switching loads such as variable frequency drives, electronic lighting, and UPS systems. Also, it's Hall Effect measurement system measures DC currents without breaking the circuit.
One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, colour display to analyse the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyser ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.
Features
- AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
- Highest safety rating: 600 V CAT IV power analyser is rated for use at the service entrance
- Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter
- Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
- Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
- Troubleshoot harmonics: Analyse and log harmonics digitally or graphically
- Inrush current: Capture and analyse nuisance tripping, from 3 seconds to 300 seconds
- Easy to use: Easily confirm power meter setup with large backlit colour display of waveforms and trends
- USB download: Download logged data with PowerLog application software to view trends and screenshots, analyse and create reports simply.
- Battery eliminator: powers the instrument when performing extended logging sessions.
- 3-Phase power: Built in capability for balanced loads
- View graphs and generate reports: Use power analyser with included Power Log software
Besides effectively performing basic tasks like measuring wattage, the Fluke 345 power meters offer the ease of use, portability and flexibility needed to resolve most power issues in commercial, industrial and residential settings.
Applications
- Setup and troubleshoot variable frequency drives and UPS systems - Verify correct operation by measuring key power quality parameters
- Harmonics measurements - Uncover harmonic issues that can damage or disrupt critical equipment
- Inrush capture - Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
- Load studies - Verify electrical system capacity before adding loads
Specifications
Current Measurement | |
Measuring Range | 0 to 2000 A DC or 1400 AC RMS |
Autorange Facility | 40 A/400 A/2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 in 2000 A range |
Accuracy | |
DC and DC RMS | I > 10 A: ±1.5% rdg ±5 digits I < 10 A: ±0.2 A |
AVG | I > 10 A: ±3% rdg ±5 digits I < 10 A: ±0.5 A |
Pk | I > 10 A: ±5% rdg ±5 digits I < 10 A: ±0.5 A |
AHr | I > 10 A: ±2% rdg ±5 digits I < 10 A: ±0.5 AHr |
CF (Crest Factor) | 1.1 ≤ CF < 3: ±3% rdg ±5 digits 3 ≤ CF < 5: ±5% rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2% ≤ RPL < 100%: ±3% rdg ±5 digits 100% ≤ RPL < 600%: ±5% rdg ± 5 digits Resolution: 0.01% |
Voltage Measurement | |
Measuring Range | 0 to 825 V DC or AC RMS |
Autorange Facility | 4 V/40 V/400 V/750 V |
Resolution | 1 mV in 4 V range 10 mV in 40 V range 100 mV in 400 V range 1 V in 750 V range |
DC and DC RMS | V > 1 V: ±1% rdg ±5 digits V < 1 V: ± 0.02 V |
AVG | V > 1 V: ±3% rdg ±5 digits V < 1 V: ± 0.03 V |
Pk | V > 1 V: ±5% rdg ±5 digits V < 1 V: ± 0.03 V |
CF (Crest Factor) | V > 1 V: ±5% rdg ±5 digits V < 1 V: ±5% rdg ± 5 digits Resolution: 0.01 |
RPL (Ripple) | 2% ≤ RPL < 100%: ±3% rdg ± 5 digits 100% ≤ RPL < 600%: ±5% rdg ± 5 digits Resolution: 0.1% |
Harmonics | |
THD (Total Harmonic Distortion) | 1% ≤ THD < 100%: ±3% rdg ± 5 digits 100% ≤ THD < 600%: ±5% rdg ± 5 digits Resolution: 0.1% |
DF (Distortion Factor) | 1% ≤ DF < 100%: ±3% rdg ± 5 digits Resolution: 0.1% H02 ≤ Vharm < H13: ±5% rdg ± 2 digits H13 ≤ Vharm ≤ H30: ± 10% rdg ± 2 digits |
Watts Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1650 kW DC or 1200 kW AC |
Autoranging Facility | 4, 40, 400, 1650 kW AC |
Resolution | 1 W in 4 kW 10 W in 40 kW 100 W in 400 kW 1 kW in 1200 kW |
Accuracy | 2.5% rdg ± 5 digits W1ø <2 kW ± 0.08 kW W3ø <4 kW ± 0.25 kW |
VA Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1650 kVA DC or 1200 kVA AC |
Autorange Facility | 4, 40, 400, 1650 kVA |
Resolution | 1 VA in 4 kVA 10 VA in 40 kVA 100 VA in 400 kVA 1 kVA in 1200 kVA |
Accuracy | VA >2 kVA: 2.5% rdg ± 5 digits VA <2 kVA: ±0.08 kVA |
VAR Measurement (Single - and Three-Phase) | |
Measuring Range | 0 to 1250 kVAR |
Autorange Facility | 4, 40, 400, 1200 kVAR |
Resolution | 1 VAR in 4 kVAR 10 VAR in 40 kVAR 100 VAR in 400 kVAR 1 kVAR in 1200 kVAR |
Accuracy | VA >4 kVAR: 2.5% rdg ± 5 digits VA <4 kVAR: ±0.25 kVAR |
Power Factor Range | 0.3 >PF <0.99 |
Power Factor (Single - and Three-Phase) | |
Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ±3° |
Frequency Range | 15 Hz to 1 kHz |
Displacement Power Factor | |
Measuring Range | 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive) |
Resolution | 0.001 |
Accuracy | ±3° |
Frequency Range | 15 to 22 Hz and 45 to 65 Hz |
Kilowatt Hour (kWHr) | |
Measuring Range | 40,000 kWHr |
Autorange Facility | 1, 40, 400, 4000, 40,000 kWHr |
Resolution | 1 WHr in 4 kWHr 10 WHr in 40 kWHr 100 WHr in 400 kWHr 1 kWHr in 4,000 kWHr 10 kWHr in 40,000 kWHr |
Accuracy | kWHr >2 kWHr: ±3% ± 5 digits kWHr <2 kWHr: ±0.08 kWHr |
All Watts /VA /VAR /PF Measurements | Frequency range: DC and 15 Hz to 1 kHz Current range: 10 to 1400 A RMS Voltage range: 1 to 825 V RMS Maximum input: 825 V RMS/1400 A RMS Maximum overload: 1000 V RMS/10,000 A |
Frequency Measurement | |
Measuring Range | 15 Hz to 1 kHz |
Resolution | 0.1 Hz |
Accuracy | 15 to 22 Hz ± 0.5% rdg 40 to 70 Hz ± 0.5% rdg 15 to 1000 Hz ± 1% rdg |
Current Range | 10 to 1400 A RMS |
Voltage Range | 1 to 825 V RMS |
Current Measurement | |
Ranges | 10/20/40/100/200/400/1000/2000 A |
Resolution | 1 A in 40 A 10 A in 400 A 50 A in 2000 A |
Accuracy | ±3% rdg ± 1 pixel |
Maximum Overload | 10,000 A |
Voltage Measurement | |
Ranges | 4/10/20/40/100/200/400/1000 V |
Resolution | 100 mV in 4 V 1 V in 40 V 10 V in 400 V 31.25 V in 1000 V |
Accuracy | ±2% rdg ± 1 pixel |
Maximum Overload | 1000 V RMS |
Frequency Range | DC and 15 to 600 Hz |
Time Base | 2.5, 5, 10, 25, 50 ms/div |
Refresh Rate | 0.5 seconds |
Maximum Sampling Rate | 15.625 kHz |
Inrush Current Function | |
Ranges | 40, 400, and 2000 A |
Resolution | 10 mA in 40 A range 100 mA in 400 A range 1 A in 2000 A range |
Accuracy | I > 10 A: ±5% rdg ± 1 pixel I < 10 A: ±0.5 A |
Maximum Overload | Maximum overload 10,000 A or RMS x frequency <400,000 |
Capture Time | 1, 3, 10, 30, 100, and 300 s |
Maximum Sampling Rate | 15.625 kHz |
Logging Memory | |
Logging Areas | Three areas that can be used individually or combined into one large area |
Averaging Periods | 1, 2, 5, 10, 30 s, 1, 5, 10, 15 min, and custom |
General Specifications | |
Display | Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight |
Power Supply | Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6 |
Battery Life Typically | >10 hours (backlight on full) >12 hours (backlight reduced) |
Battery Eliminator BE345 | Input: 110/230 V, 50/60 Hz Output: 15 V DC, 300 mA |
Reference Conditions | All accuracies stated at 73.4 ± 1.8°F (23 ± 1°C) |
Operating Temperature | 32 to 122°F (0 to 50°C) |
Temperature Coefficient of Current | ≤± 0.15% of rdg per °C |
Temperature Coefficient of Voltage | ≤± 0.15% of rdg per °C |
Maximum Relative Humidity | 80 % for temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F (40°C) |
Maximum Operating Altitude | 6561.7' (2000 m) |
Mechanical | |
Cleaning | The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents. |
Jaw Capacity | 2.3" (58 mm) diameter |
Jaw Opening | 2.4" (60 mm) |
Dimensions | 12 x 3.75 x 2" (300 x 98 x 52 mm |
Weight | 1.8 lbs (820 g) batteries included |
Electrical Safety | |
Maximum Safe Working Voltages | Current measurement: 600 V AC RMS or DC between uninsulated conductor and ground Voltage measurement: 600 V AC RMS or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.) |
EMC | |
Emission | IEC/EN 61326-1:1997 class B |
Immunity | IEC/EN 61326-1:1997 |
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.