9143 Field Metrology Small dry Wells for big field applications

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 3054558, 3054573, 3054599, 3054618, 3054634, 3054652, 3054676, 3054690, 3054736, 3054751, 3054772, 3054797, 3054810, 3054831)

Small dry wells for big field applications

The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.

Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.

High performance for the industrial environment

Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.

Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.


FEATURES

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

MODEL SPECIFICATIONS

Fluke 9143-A-156

Fluke Calibration 9143-A-156 Field Metrology Well
Insert “A”, imperial misc. holes
33°C to 350°C


Fluke 9143-B-156

Fluke Calibration 9143-B-156 Field Metrology Well
Insert “B”, imperial comparison holes
33°C to 350°C

Fluke 9143-C-156

Fluke Calibration 9143-C-156 Field Metrology Well
Insert “C”, 0.25-inch holes
33°C to 350°C

Fluke 9143-D-156

Fluke Calibration 9143-D-156 Field Metrology Well
Insert “D”, metric comparison holes
33°C to 350°C

Fluke 9143-E-156

Fluke Calibration 9143-E-156 Field Metrology Well
Insert “E”, metric misc. holes w/ 0.25-inch hole
33°C to 350°C

Fluke 9143-F-156

Fluke Calibration 9143-F-156 Field Metrology Well
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
33°C to 350°C

Fluke 9143-DW-156

Fluke Calibration 9143-DW-156 Field Metrology Well
Insert “DW”, metric comparison holes
33°C to 350°C

Fluke 9143-A-P-156

Fluke Calibration 9143-A-P-156 Field Metrology Well
Insert “A”, imperial misc. holes
33°C to 350°C, w/ process electronics

Fluke 9143-B-P-156

Fluke Calibration 9143-B-P-156 Field Metrology Well
Insert “B”, imperial comparison holes
33°C to 350°C, w/ process electronics

Fluke 9143-C-P-156

Fluke Calibration 9143-C-P-156 Field Metrology Well
Insert “C”, 0.25-inch holes
33°C to 350°C, w/ process electronics

Fluke 9143-D-P-156

Fluke Calibration 9143-D-P-156 Field Metrology Well
Insert “D”, metric comparison holes
33°C to 350°C, w/ process electronics

Fluke 9143-E-P-156

Fluke Calibration 9143-E-P-156 Field Metrology Well
Insert “E”, metric misc. holes w/ 0.25-inch hole
33°C to 350°C, w/ process electronics

Fluke 9143-F-P-156

Fluke Calibration 9143-F-P-156 Field Metrology Well
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
33°C to 350°C, w/ process electronics

Fluke 9143-DW-P-156

Fluke Calibration 9143-DW-P-156 Field Metrology Well
Insert “D”, metric comparison holes
33°C to 350°C, w/ process electronics


GENERAL SPECIFICATIONS

Temperature range at 23°C 33°C to 350°C (91°F to 662°F)
Display accuracy ±0.2°C Full Range
Stability ±0.02°C at 33°C
±0.02°C at 200°C
±0.03°C at 350°C
Axial uniformity at 40 mm (1.6 in) ±0.04°C at 33°C
±0.1°C at 200°C
±0.2°C at 350°C
Radial uniformity ±0.01°C at 33°C
±0.015°C at 200°C
±0.02°C at 350°C
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) ±0.015°C Full Range
Hysteresis 0.03
Operating conditions 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental conditions (for all specifications except temperature range) 13°C to 33°C
Immersion (well) depth 150 mm (5.9 in)
Insert OD 25.3 mm (1.00 in)
Heating time 5 min: 33°C to 350°C
Cooling time 32 min: 350°C to 33°C
14 min: 350°C to 100°C
Resolution 0.01°
Display LCD, °C or °F user-selectable
Size (H x W x D) 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight 7.3 kg (16 lb)
Power requirements 100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Computer interface RS-232 interface
Calibration NVLAP accredited calibration included
Automation Use the 1586A Super-DAQ to automate temperature sensor calibration
-P specifications
Built-in reference thermometer readout accuracy (4-Wire reference probe)1 ±0.010°C at -25°C
±0.015°C at 0°C
±0.020°C at 50°C
±0.025°C at 150°C
±0.030°C at 200°C
±0.040°C at 350°C
±0.050°C at 420°C
±0.070°C at 660°C
Reference resistance range 0 ohms to 400 ohms
Reference resistance accuracy2 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizations ITS-90, CVD, IEC-751, Resistance
Reference measurement capability 4-wire
Reference probe connection 6-pin Din with Infocon Technology
Built-in RTD thermometer readout accuracy NI-120: ±0.015°C at 0°C
PT-100 (385): ±0.02°C at 0°C
PT-100 (3926): ±0.02°C at 0°C
PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range 0 ohms to 400 ohms
RTD resistance accuracy‡ 0 ohms to 25 ohms: ±0.002 ohms
25 ohms to 400 ohms: ±80 ppm of reading
RTD characterizations  PT-100 (385),(JIS),(3926), NI-120, Resistance
RTD measurement capability 4-wire RTD (2-,3-wire RTD w\ Jumpers only)
RTD connection 4 terminal input
Built-in TC thermometer readout accuracy Type J: ±0.7°C at 660°C
Type K: ±0.8°C at 660°C
Type T: ±0.8°C at 400°C
Type E: ±0.7°C at 660°C
Type R: ±1.4°C at 660°C
Type S: ±1.5°C at 660°C
Type M: ±1.4°C at 660°C
Type L: ±0.7°C at 660°C
Type U: ±0.75°C at 600°C
Type N: ±0.9°C at 660°C
Type C: ±1.1°C at 660°C
TC millivolt range –10 mV to 75 mV
Voltage accuracy 0.025% of reading + 0.01 mV
Internal cold junction compensation accuracy ±0.35°C (ambient of 13°C to 33°C)
TC connection Small connectors
Built-in mA readout accuracy 0.02% of reading + 2 mV
mA range Cal 4-22 mA, Spec 4-24 mA
mA connection 2 terminal input
Loop power function 24 V DC loop power
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C) ±0.005% of range per °C
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.
2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.
Shipping This Item Ships from Fremantle, Perth, Western Australia
Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Description

9143 Field Metrology Small dry Wells for big field applications

(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )

(item no. 3054558, 3054573, 3054599, 3054618, 3054634, 3054652, 3054676, 3054690, 3054736, 3054751, 3054772, 3054797, 3054810, 3054831)

Small dry wells for big field applications

The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.

Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.

High performance for the industrial environment

Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.

Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.


FEATURES

  • Lightweight, portable, and fast
  • Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
  • True reference thermometry with accuracy to ±0.01 °C
  • On-board automation and documentation
  • Metrology performance in accuracy, stability, uniformity, and loading

MODEL SPECIFICATIONS

Fluke 9143-A-156

Fluke Calibration 9143-A-156 Field Metrology Well
Insert “A”, imperial misc. holes
33°C to 350°C


Fluke 9143-B-156

Fluke Calibration 9143-B-156 Field Metrology Well
Insert “B”, imperial comparison holes
33°C to 350°C

Fluke 9143-C-156

Fluke Calibration 9143-C-156 Field Metrology Well
Insert “C”, 0.25-inch holes
33°C to 350°C

Fluke 9143-D-156

Fluke Calibration 9143-D-156 Field Metrology Well
Insert “D”, metric comparison holes
33°C to 350°C

Fluke 9143-E-156

Fluke Calibration 9143-E-156 Field Metrology Well
Insert “E”, metric misc. holes w/ 0.25-inch hole
33°C to 350°C

Fluke 9143-F-156

Fluke Calibration 9143-F-156 Field Metrology Well
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
33°C to 350°C

Fluke 9143-DW-156

Fluke Calibration 9143-DW-156 Field Metrology Well
Insert “DW”, metric comparison holes
33°C to 350°C

Fluke 9143-A-P-156

Fluke Calibration 9143-A-P-156 Field Metrology Well
Insert “A”, imperial misc. holes
33°C to 350°C, w/ process electronics

Fluke 9143-B-P-156

Fluke Calibration 9143-B-P-156 Field Metrology Well
Insert “B”, imperial comparison holes
33°C to 350°C, w/ process electronics

Fluke 9143-C-P-156

Fluke Calibration 9143-C-P-156 Field Metrology Well
Insert “C”, 0.25-inch holes
33°C to 350°C, w/ process electronics

Fluke 9143-D-P-156

Fluke Calibration 9143-D-P-156 Field Metrology Well
Insert “D”, metric comparison holes
33°C to 350°C, w/ process electronics

Fluke 9143-E-P-156

Fluke Calibration 9143-E-P-156 Field Metrology Well
Insert “E”, metric misc. holes w/ 0.25-inch hole
33°C to 350°C, w/ process electronics

Fluke 9143-F-P-156

Fluke Calibration 9143-F-P-156 Field Metrology Well
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
33°C to 350°C, w/ process electronics

Fluke 9143-DW-P-156

Fluke Calibration 9143-DW-P-156 Field Metrology Well
Insert “D”, metric comparison holes
33°C to 350°C, w/ process electronics


GENERAL SPECIFICATIONS

Temperature range at 23°C 33°C to 350°C (91°F to 662°F)
Display accuracy ±0.2°C Full Range
Stability ±0.02°C at 33°C
±0.02°C at 200°C
±0.03°C at 350°C
Axial uniformity at 40 mm (1.6 in) ±0.04°C at 33°C
±0.1°C at 200°C
±0.2°C at 350°C
Radial uniformity ±0.01°C at 33°C
±0.015°C at 200°C
±0.02°C at 350°C
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) ±0.015°C Full Range
Hysteresis 0.03
Operating conditions 0°C to 50°C, 0% to 90% RH (non-condensing)
Environmental conditions (for all specifications except temperature range) 13°C to 33°C
Immersion (well) depth 150 mm (5.9 in)
Insert OD 25.3 mm (1.00 in)
Heating time 5 min: 33°C to 350°C
Cooling time 32 min: 350°C to 33°C
14 min: 350°C to 100°C
Resolution 0.01°
Display LCD, °C or °F user-selectable
Size (H x W x D) 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in)
Weight 7.3 kg (16 lb)
Power requirements 100 V to 115 V (±10%), 50/60 Hz, 1400 W 230 V (±10%), 50/60 Hz, 1800 W
Computer interface RS-232 interface
Calibration NVLAP accredited calibration included
Automation Use the 1586A Super-DAQ to automate temperature sensor calibration
-P specifications
Built-in reference thermometer readout accuracy (4-Wire reference probe)1 ±0.010°C at -25°C
±0.015°C at 0°C
±0.020°C at 50°C
±0.025°C at 150°C
±0.030°C at 200°C
±0.040°C at 350°C
±0.050°C at 420°C
±0.070°C at 660°C
Reference resistance range 0 ohms to 400 ohms
Reference resistance accuracy2 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading
Reference characterizations ITS-90, CVD, IEC-751, Resistance
Reference measurement capability 4-wire
Reference probe connection 6-pin Din with Infocon Technology
Built-in RTD thermometer readout accuracy NI-120: ±0.015°C at 0°C
PT-100 (385): ±0.02°C at 0°C
PT-100 (3926): ±0.02°C at 0°C
PT-100 (JIS): ±0.02°C at 0°C
RTD resistance range 0 ohms to 400 ohms
RTD resistance accuracy‡ 0 ohms to 25 ohms: ±0.002 ohms
25 ohms to 400 ohms: ±80 ppm of reading
RTD characterizations  PT-100 (385),(JIS),(3926), NI-120, Resistance
RTD measurement capability 4-wire RTD (2-,3-wire RTD w\ Jumpers only)
RTD connection 4 terminal input
Built-in TC thermometer readout accuracy Type J: ±0.7°C at 660°C
Type K: ±0.8°C at 660°C
Type T: ±0.8°C at 400°C
Type E: ±0.7°C at 660°C
Type R: ±1.4°C at 660°C
Type S: ±1.5°C at 660°C
Type M: ±1.4°C at 660°C
Type L: ±0.7°C at 660°C
Type U: ±0.75°C at 600°C
Type N: ±0.9°C at 660°C
Type C: ±1.1°C at 660°C
TC millivolt range –10 mV to 75 mV
Voltage accuracy 0.025% of reading + 0.01 mV
Internal cold junction compensation accuracy ±0.35°C (ambient of 13°C to 33°C)
TC connection Small connectors
Built-in mA readout accuracy 0.02% of reading + 2 mV
mA range Cal 4-22 mA, Spec 4-24 mA
mA connection 2 terminal input
Loop power function 24 V DC loop power
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C) ±0.005% of range per °C
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.
2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires.

Shipping

Shipping This item ships to

Delivery & Returns

Please allow 2 - 10 days for your order to arrive.

Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!

Returns are easy.

simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

Reviews

6 Great reasons to buy from us:

  • Image of If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.

    30 Days Return

    If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you.
  • Image of Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!

    Returns are Easy

    Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
  • Image of In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.

    Best Price Guarantee

    In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down.
  • Image of We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.

    We guarantee your satisfaction

    We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again.
  • Image of Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.

    100% Safe & Secure

    Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either.
  • Image of Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.

    Best Laser Warranties in the Business

    Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.
Fluke 9143 Field Metrology Small dry Wells for big field applications

Fluke 9143 Field Metrology Small dry Wells for big field applications

£4,993.00
Fluke 9143 Field Metrology Small dry Wells for big field applications

Fluke 9143 Field Metrology Small dry Wells for big field applications

£4,993.00

Recently viewed products