1586A Super-DAQ 2 DAQ-STAQ Modules 240V
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 4410023)
The 1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for bench top sensor calibration in the lab.
It collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyse interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analysing the data on a PC.
When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best bench top reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples. Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration dry well or bath and Automated Sensor Test routines are run.
Some temperature data acquisition applications require compliance to government and standards agency requirements. TQSoft and TQAero thermal validation software help engineers, technicians and lab managers to meet the key guidelines for temperature data collection. These software solutions provide a complete qualification, reporting, documentation, and audit trail management system.
FEATURES
- The 1586A Super-DAQ reads PRTs, thermocouples, and thermistors with best-in-class accuracy:
- PRTs ± 0.005 °C (using external DAQ-STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Chart up to four channels simultaneously
- Administrator and user profiles for protecting settings and ensuring test traceability
- Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive.
- Transfer data to a PC using the USB drive or LAN connection
- Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Input channels: Up to 40 isolated universal inputs
- Selectable scan speed: Up to 10 channels per second
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
- Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance
- Current reversal minimises thermoelectric effects, improving PRT/RTD measurement accuracy
- Two rear panel slots can be configured for the internal High-Capacity Module or the external DAQ-STAQ Multiplexer - or one of each
- Navigation keys for fast selection of information
- Standby key turns the display and keypad off which eliminates warm-up time
- Function soft keys support fast setup and operation
- Measure/DMM function for quick measurements and recording with minimal setup
- Line voltage and fuse selector
- Power switch and line cord connector
- USB and Ethernet ports used for remote operation
- Digital external alarm trigger outputs
- Mx + B scaling and channel offset zero function
- Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
APPLICATIONS
- Thermal mapping
- Temperature validation
- Process sensor calibration
- Automotive
- Pharmaceutical
- Biotechnology
- Food processing
- Aerospace
SPECIFICATIONS
PRT/RTD (100 Ω Nominal) | |
Temperature Range | -200 to 1200°C (depending on the sensor) |
Temperature Resolution | 0.001°C |
Temperature Accuracy | 0.005°C at -200°C 0.005°C at 0°C 0.012°C at 300°C |
Resistance Accuracy | 0.002% or 0.008 Ω |
Excitation Current | 1 mA with current reversal |
Thermistor (10 KΩ Nominal) | |
Temperature Range | -200 to 400°C (depending on the sensor) |
Temperature Resolution | 0.0001°C |
Temperature Accuracy | 0.002°C at 0°C 0.009°C at 50°C 0.024°C at 100°C |
Resistance Accuracy | 0.004% + 0.5 Ω |
Excitation Current | 10 μA |
Thermocouple Type K | |
Temperature Range | -270 to 1372°C |
Temperature Resolution | 0.01°C/td> |
Temperature Accuracy (int CJC) | 0.29°C at 0°C 0.32°C at 1000°C |
Temperature Accuracy (ext CJC) | 0.15°C at 0°C 0.20°C at 1000°C |
Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
Thermocouple Type T | |
Temperature Range | -270 to 400°C |
Temperature Resolution | 0.01°C |
Temperature Accuracy (int CJC) | 0.30°C at 0°C 0.23°C at 200°C |
Temperature Accuracy (ext CJC) | 0.15°C at 0°C 0.12°C at 200°C |
Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
Thermocouple Type S | |
Temperature Range | -50 to 1768°C |
Temperature Resolution | 0.01°C |
Temperature Accuracy (int CJC) | 0.68°C at 300°C 0.55°C at 1200°C |
Temperature Accuracy (ext CJC) | 0.67°C at 300°C 0.54°C at 1200°C |
Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
DC Voltage (Medium or Slow Sample Rate) | |
Range | ±100 mV ±50 V |
Accuracy Channel 1 | 0.0037% + 0.0035% 0.0038% + 0.0012% |
Ch. X01 - x202 | Add 2 μV |
Fast Sample Rate | Add 0.0008% of range |
Resolution | 0.1 μV 1 mV |
Input Impedance | 10 GΩ [1] 10 MΩ ±1% |
DC Current (Medium or Slow Sample Rate) | |
Range | ±100 μA ±10 mA ±100 mA |
Accuracy | 0.015% + 0.0035% |
Fast Sample Rate | Add 0.0008% of range |
Resolution | 0.1 nA 10 nA 100 nA |
Burden Voltage | <1 mV |
Resistance (Medium or Slow Sample Rate, 4-Wire Resistance) | |
Range | 100 Ω 10 kΩ 10 MΩ |
Accuracy | 0.004% + 0.0035% 0.004% + 0.001% 0.015% + 0.001% |
Fast Sample Rate | Add 0.001% of range Add 0.01% of range |
Resolution | 0.1 mΩ 10 mΩ 1 kΩ |
Source Current | 1 mA 100 μA 0.1 μA |
General Specifications | |
Channel Capacity | Total analog channels: 45 Voltage/resistance channels: 41 Current channels: 5 Digital I/O: 1 (8-bit TTL) Totalizer: 1 Alarm outputs: 6 Trigger input: 1 |
Sample Rate | Fast: 10 channels per second (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel) Slow: 4 seconds per channel |
Display Resolution | 6 1/2 digits |
Input Module Options | 2 rear panel slots ('x' designates slot 1 or slot 2 below) |
Internal High-Capacity Module configuration | 20 channels per module (x01 - x20) 2 dedicated current channels (x21 - x22) (3- and 4-wire connections require 2 channels) |
Math Channels | 20 channels Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum |
Triggers | Interval, external (trigger input), alarm, remote (bus), manual, automated test |
Memory | Scan data RAM: 75,000 readings with timestamp Internal memory: 20 MB |
Standard Interfaces | USB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths |
Mains Voltage | 100 V setting: 90 to 100 V 120 V setting: 108 to 132 V 220 V setting: 198 to 242 V 240 V setting: 216 to 264 V |
Mains Frequency | 47 to 440 Hz |
Input Protection | 50 V all functions, terminals and ranges |
Dimensions | 5.9 x 9.6 x 15.2" (150 x 245 x 385 mm) |
Weight | 13.2 lbs (6 kg) |
Conformity | CE, CSA, IEC 61010 3rd edition |
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
1586A Super-DAQ 2 DAQ-STAQ Modules 240V
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 4410023)
The 1586A Super‑DAQ is the most accurate and flexible temperature data acquisition system on the market. It scans and records temperature, dc voltage, dc current, and resistance for up to 40 input channels and scan speeds as fast as 10 channels per second. The Super-DAQ can be configured for use as a multi-channel data logger in the factory or as a precision reference thermometer for bench top sensor calibration in the lab.
It collects time-stamped precision temperature and electrical measurements for data analysis by technicians, engineers, and quality control personnel to verify process control, analyse interactive systems, ensure conformance to quality standards, or to correlate related events for R&D or troubleshooting. Measurement data and statistics can be viewed in tabular format for all active channels. With the graphing feature, up to four channels can be plotted at the same time, making it easy to quickly assess test setup and results before analysing the data on a PC.
When configured with the DAQ-STAQ Multiplexer, the Super-DAQ has the accuracy of the best bench top reference thermometer readouts for calibration of PRTs, RTDs, thermistors, or thermocouples. Lab efficiency can be increased when the Super-DAQ is connected to a Fluke Calibration dry well or bath and Automated Sensor Test routines are run.
Some temperature data acquisition applications require compliance to government and standards agency requirements. TQSoft and TQAero thermal validation software help engineers, technicians and lab managers to meet the key guidelines for temperature data collection. These software solutions provide a complete qualification, reporting, documentation, and audit trail management system.
FEATURES
- The 1586A Super-DAQ reads PRTs, thermocouples, and thermistors with best-in-class accuracy:
- PRTs ± 0.005 °C (using external DAQ-STAQ Multiplexer)
- Thermocouples: ± 0.5 °C (using High-Capacity Module and internal CJC)
- Thermistors: ± 0.002 °C
- Four modes of operation: Scan, Monitor, Measure, Digital Multimeter (DMM)
- Chart up to four channels simultaneously
- Administrator and user profiles for protecting settings and ensuring test traceability
- Records up to 20 MB of data and setup files to internal non-volatile memory or to an external USB drive.
- Transfer data to a PC using the USB drive or LAN connection
- Control Fluke Calibration temperature sources such as dry-wells or micro-baths for automated calibration routines
- Input channels: Up to 40 isolated universal inputs
- Selectable scan speed: Up to 10 channels per second
- Alarms: Two independent, user-defined alarms for each channel indicate when an upper or lower range has been exceeded
- Measure thermocouples, PRTs, thermistors, dc voltage, dc current, and resistance
- Current reversal minimises thermoelectric effects, improving PRT/RTD measurement accuracy
- Two rear panel slots can be configured for the internal High-Capacity Module or the external DAQ-STAQ Multiplexer - or one of each
- Navigation keys for fast selection of information
- Standby key turns the display and keypad off which eliminates warm-up time
- Function soft keys support fast setup and operation
- Measure/DMM function for quick measurements and recording with minimal setup
- Line voltage and fuse selector
- Power switch and line cord connector
- USB and Ethernet ports used for remote operation
- Digital external alarm trigger outputs
- Mx + B scaling and channel offset zero function
- Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection
- 6 1/2 digit display resolution for dc voltage, dc current, and resistance
APPLICATIONS
- Thermal mapping
- Temperature validation
- Process sensor calibration
- Automotive
- Pharmaceutical
- Biotechnology
- Food processing
- Aerospace
SPECIFICATIONS
PRT/RTD (100 Ω Nominal) | |
Temperature Range | -200 to 1200°C (depending on the sensor) |
Temperature Resolution | 0.001°C |
Temperature Accuracy | 0.005°C at -200°C 0.005°C at 0°C 0.012°C at 300°C |
Resistance Accuracy | 0.002% or 0.008 Ω |
Excitation Current | 1 mA with current reversal |
Thermistor (10 KΩ Nominal) | |
Temperature Range | -200 to 400°C (depending on the sensor) |
Temperature Resolution | 0.0001°C |
Temperature Accuracy | 0.002°C at 0°C 0.009°C at 50°C 0.024°C at 100°C |
Resistance Accuracy | 0.004% + 0.5 Ω |
Excitation Current | 10 μA |
Thermocouple Type K | |
Temperature Range | -270 to 1372°C |
Temperature Resolution | 0.01°C/td> |
Temperature Accuracy (int CJC) | 0.29°C at 0°C 0.32°C at 1000°C |
Temperature Accuracy (ext CJC) | 0.15°C at 0°C 0.20°C at 1000°C |
Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
Thermocouple Type T | |
Temperature Range | -270 to 400°C |
Temperature Resolution | 0.01°C |
Temperature Accuracy (int CJC) | 0.30°C at 0°C 0.23°C at 200°C |
Temperature Accuracy (ext CJC) | 0.15°C at 0°C 0.12°C at 200°C |
Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
Thermocouple Type S | |
Temperature Range | -50 to 1768°C |
Temperature Resolution | 0.01°C |
Temperature Accuracy (int CJC) | 0.68°C at 300°C 0.55°C at 1200°C |
Temperature Accuracy (ext CJC) | 0.67°C at 300°C 0.54°C at 1200°C |
Voltage Accuracy | 0.004% + 4 μV ch. 1 0.004% + 6 μV ch. x01-x20 |
DC Voltage (Medium or Slow Sample Rate) | |
Range | ±100 mV ±50 V |
Accuracy Channel 1 | 0.0037% + 0.0035% 0.0038% + 0.0012% |
Ch. X01 - x202 | Add 2 μV |
Fast Sample Rate | Add 0.0008% of range |
Resolution | 0.1 μV 1 mV |
Input Impedance | 10 GΩ [1] 10 MΩ ±1% |
DC Current (Medium or Slow Sample Rate) | |
Range | ±100 μA ±10 mA ±100 mA |
Accuracy | 0.015% + 0.0035% |
Fast Sample Rate | Add 0.0008% of range |
Resolution | 0.1 nA 10 nA 100 nA |
Burden Voltage | <1 mV |
Resistance (Medium or Slow Sample Rate, 4-Wire Resistance) | |
Range | 100 Ω 10 kΩ 10 MΩ |
Accuracy | 0.004% + 0.0035% 0.004% + 0.001% 0.015% + 0.001% |
Fast Sample Rate | Add 0.001% of range Add 0.01% of range |
Resolution | 0.1 mΩ 10 mΩ 1 kΩ |
Source Current | 1 mA 100 μA 0.1 μA |
General Specifications | |
Channel Capacity | Total analog channels: 45 Voltage/resistance channels: 41 Current channels: 5 Digital I/O: 1 (8-bit TTL) Totalizer: 1 Alarm outputs: 6 Trigger input: 1 |
Sample Rate | Fast: 10 channels per second (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel) Slow: 4 seconds per channel |
Display Resolution | 6 1/2 digits |
Input Module Options | 2 rear panel slots ('x' designates slot 1 or slot 2 below) |
Internal High-Capacity Module configuration | 20 channels per module (x01 - x20) 2 dedicated current channels (x21 - x22) (3- and 4-wire connections require 2 channels) |
Math Channels | 20 channels Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum |
Triggers | Interval, external (trigger input), alarm, remote (bus), manual, automated test |
Memory | Scan data RAM: 75,000 readings with timestamp Internal memory: 20 MB |
Standard Interfaces | USB host, USB device, Ethernet 10/100 LAN, RS-232 temperature source control for automated temperature data collection from Fluke Calibration drywells and baths |
Mains Voltage | 100 V setting: 90 to 100 V 120 V setting: 108 to 132 V 220 V setting: 198 to 242 V 240 V setting: 216 to 264 V |
Mains Frequency | 47 to 440 Hz |
Input Protection | 50 V all functions, terminals and ranges |
Dimensions | 5.9 x 9.6 x 15.2" (150 x 245 x 385 mm) |
Weight | 13.2 lbs (6 kg) |
Conformity | CE, CSA, IEC 61010 3rd edition |
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.