(item no. 2631538)
Product overview
One Tool. Get More Done.
The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimise HVAC ventilation settings for ASHRAE 62 recommendations, to actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time. The Fluke 975 measures:
- Temperature
- Velocity
- Humidity
- CO2
- CO
Use the Fluke 975 AirMeter test tool to:
- Respond to comfort-related calls from occupants.
- Verify the operation of building HVAC control systems.
- Determine whether adequate ventilation exists.
- Monitor air flow and velocity.
- Test for dangerous carbon monoxide leaks.
- Perform duct traversals.
- Optimise HVAC systems to manage energy costs
Features
- Simultaneously measures, logs, and displays temperature, humidity, CO 2 , and CO on a bright, backlit LCD display
- One-touch air flow and velocity with available probe*
- Wet bulb and dew point temperature
- % of outside air calculation
- CO 2 and CO field calibration feature
- Self-test function at startup
- Auto-backlight
- Automatically compensates for barometric pressure changes
- Min/Max/Average on all measured and calculated readings
- Multi-language user interface
- Metric or standard units
- Audible and visual threshold alarms
- Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
- Keypad lock for security
- Included FlukeView Forms® software
*Included with Fluke 975V, optional with Fluke 975
Specifications: Fluke 975V AirMeter™ with Velocity Probe
Measured Specifications | ||
Temperature | Range | -20°C to 50°C (-5°F to 122°F) |
Display resolution | 0.1°C (0.1°F) | |
Accuracy | ±0.9°C / ±1.62°F from 40°C to 60°C ±0.5°C / ±1.00°F from 5°C to 40°C ±1.1°C / ±1.98°F from -20°C to 5°C |
|
Relative humidity | Range | 10% to 90% RH, non-condensing |
Display Resolution | 1% | |
Accuracy | ±2% RH (10% RH to 90% RH) | |
Air velocity | Range | 50.0 fpm to 3000 fpm 0.25 m/sec to 15 m/sec |
Display Resolution | 1 fpm (0.005 m/sec) | |
Accuracy | ±4% or 4 fpm1 ±4% or 0.02 m/sec1 whichever is greater |
|
1. Accuracy specification only valid for velocity readings above 50 fpm. | ||
C0 | Range | 0 to 500 ppm |
Display Resolution | 1 ppm | |
Accuracy | ±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH | |
C02 | Range | 0 to 5000 ppm |
Display Resolution | 1 ppm | |
Accuracy | Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm | |
Calculated Specifications | ||
Dew point temperature | Range | -44°C to 50°C, (-47°F to 122°F) |
Display Resolution | 0.1°C (0.1°F) | |
Accuracy | ±1°C when temp: -20°C to 50°C RH: 40% to 90% ±2°C when temp: -20°C to 50°C RH: 20% to 40% ±4°C when RH: 10% to 20% |
|
Wet bulb temperature | Range | -16°C to 50°C, (3°F to 122°F) |
Display Resolution | 0.1°C, (0.1°F) | |
Accuracy | ±1.2°C when RH: 20% to 90% temp: -20°C to 60°C ±2.1°C when RH: 10% to 20% |
|
Volume flow rate (in a duct) | Range | 0 to 3,965 M3/m, (0 to 140,000 cfm) |
Display Resolution | 0.001 M3/min, (1 cfm) | |
Accuracy | N/A: The volume flow calculation will be a simple average of the data points times the duct area | |
% outside air (based on temperature) | Range | 0 to 100% |
Display Resolution | 0.1 | |
% outside air (based on CO2) | Range | 0 to 100% |
Display Resolution | 0.1% N/A | |
General Specifications | ||
Operating and storage temperature | -20°C to 50°C (-4°F to 122°F) | |
Humidity | 10% to 90% (non-condensing) | |
Altitude | Up to 2000 m (6562 ft) | |
Shock and vibration | MIL-PRF-28800F: Class 2 | |
Multi-language interface | English, French, Spanish, Portuguese and German | |
Battery | Rechargeable Li-Ion (primary), three-AA (backup) | |
Data logging | 25,000 records (continuous), 99 records (discrete) | |
Warranty | Two-years |
Manuals
Data sheets
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
(item no. 2631538)
Product overview
One Tool. Get More Done.
The Fluke 975 AirMeter test tool raises indoor air monitoring to the next level by combining five powerful tools in one, rugged and easy-to-use handheld device. Use the Fluke 975 to optimise HVAC ventilation settings for ASHRAE 62 recommendations, to actively monitor conditions that promote a productive environment, and quickly and accurately address occupant comfort complaints the first time. The Fluke 975 measures:
- Temperature
- Velocity
- Humidity
- CO2
- CO
Use the Fluke 975 AirMeter test tool to:
- Respond to comfort-related calls from occupants.
- Verify the operation of building HVAC control systems.
- Determine whether adequate ventilation exists.
- Monitor air flow and velocity.
- Test for dangerous carbon monoxide leaks.
- Perform duct traversals.
- Optimise HVAC systems to manage energy costs
Features
- Simultaneously measures, logs, and displays temperature, humidity, CO 2 , and CO on a bright, backlit LCD display
- One-touch air flow and velocity with available probe*
- Wet bulb and dew point temperature
- % of outside air calculation
- CO 2 and CO field calibration feature
- Self-test function at startup
- Auto-backlight
- Automatically compensates for barometric pressure changes
- Min/Max/Average on all measured and calculated readings
- Multi-language user interface
- Metric or standard units
- Audible and visual threshold alarms
- Extensive discrete or continuous data logging capacity, downloadable to PC via USB interface
- Keypad lock for security
- Included FlukeView Forms® software
*Included with Fluke 975V, optional with Fluke 975
Specifications: Fluke 975V AirMeter™ with Velocity Probe
Measured Specifications | ||
Temperature | Range | -20°C to 50°C (-5°F to 122°F) |
Display resolution | 0.1°C (0.1°F) | |
Accuracy | ±0.9°C / ±1.62°F from 40°C to 60°C ±0.5°C / ±1.00°F from 5°C to 40°C ±1.1°C / ±1.98°F from -20°C to 5°C |
|
Relative humidity | Range | 10% to 90% RH, non-condensing |
Display Resolution | 1% | |
Accuracy | ±2% RH (10% RH to 90% RH) | |
Air velocity | Range | 50.0 fpm to 3000 fpm 0.25 m/sec to 15 m/sec |
Display Resolution | 1 fpm (0.005 m/sec) | |
Accuracy | ±4% or 4 fpm1 ±4% or 0.02 m/sec1 whichever is greater |
|
1. Accuracy specification only valid for velocity readings above 50 fpm. | ||
C0 | Range | 0 to 500 ppm |
Display Resolution | 1 ppm | |
Accuracy | ±5% or ±3 ppm, whichever is greater, @ 20°C and 50% RH | |
C02 | Range | 0 to 5000 ppm |
Display Resolution | 1 ppm | |
Accuracy | Warm up time 1 min (5 minutes for full specification) 2.75% + 75 ppm | |
Calculated Specifications | ||
Dew point temperature | Range | -44°C to 50°C, (-47°F to 122°F) |
Display Resolution | 0.1°C (0.1°F) | |
Accuracy | ±1°C when temp: -20°C to 50°C RH: 40% to 90% ±2°C when temp: -20°C to 50°C RH: 20% to 40% ±4°C when RH: 10% to 20% |
|
Wet bulb temperature | Range | -16°C to 50°C, (3°F to 122°F) |
Display Resolution | 0.1°C, (0.1°F) | |
Accuracy | ±1.2°C when RH: 20% to 90% temp: -20°C to 60°C ±2.1°C when RH: 10% to 20% |
|
Volume flow rate (in a duct) | Range | 0 to 3,965 M3/m, (0 to 140,000 cfm) |
Display Resolution | 0.001 M3/min, (1 cfm) | |
Accuracy | N/A: The volume flow calculation will be a simple average of the data points times the duct area | |
% outside air (based on temperature) | Range | 0 to 100% |
Display Resolution | 0.1 | |
% outside air (based on CO2) | Range | 0 to 100% |
Display Resolution | 0.1% N/A | |
General Specifications | ||
Operating and storage temperature | -20°C to 50°C (-4°F to 122°F) | |
Humidity | 10% to 90% (non-condensing) | |
Altitude | Up to 2000 m (6562 ft) | |
Shock and vibration | MIL-PRF-28800F: Class 2 | |
Multi-language interface | English, French, Spanish, Portuguese and German | |
Battery | Rechargeable Li-Ion (primary), three-AA (backup) | |
Data logging | 25,000 records (continuous), 99 records (discrete) | |
Warranty | Two-years |
Manuals
Data sheets
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.