Fluke Oil Deadweight Testers
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 4185566, 4185575, 4185582, 4185594, 4185608, 4185613, 4185624, 4185636, 4185649)
- Pressure ranges to 60,000 psi (4000 bar)
- Select from two accuracy classes; 0.02% or 0.015% of reading
- Includes hand pump and intensifier for generating high pressures
- Tungsten carbide piston and cylinder provides long term stability and durability
- Mass set can be trimmed to local gravity FOC
The Pressurements P3800 Series High Pressure Hydraulic Deadweight Testers are the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features and options designed to improve accuracy, increase reliability, and simplify operation, the P3800 Series can be used to calibrate virtually any high pressure sensing device including transducers, transmitters, gauges, pressure switches or other calibrators.
Three models are available, P3830, P3840 and P3860 offering pressure ranges of 30,000, 40,000 and 60,000 psi respectively (2000, 3000 and 4000 bar). All models are available in two accuracy classes, 0.02% or 0.015% of Reading. The Series P3800 offers an accurate and economical approach to calibrating high pressure devices.
Models & Accessories
Specifications
Pressure Ranges |
|
P3830 | 500 to 30,000 psi, or 40 to 2,000 bar, or 4 to 200 MPa, or 40 to 2000 kgf/cm2 |
P3840 | 500 to 40,000 psi, or 40 to 2,600 bar, or 4 to 260 MPa, or 40 to 2600 kgf/cm2 |
P3860 | 500 to 60,000 psi or 40 to 4,000 bar or 4 to 400 MPa or 40 to 4000 kgf/cm2 |
Accuracy |
|
Accuracy* | Standard accuracy is 0.02% of Reading*. Optional accuracy of 0.015% of Reading is available. ISO/IEC 17025 accredited calibration is provided with each instrument. *Accuracy is based on % of Reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10%, ± (accuracy class) x 10% of the piston range. See the “Guide for the Uncertainty Analysis in Pressure when Using P3000 Series Deadweight Testers” technical note for more information. |
Materials of Construction |
|
Standard weight material | Series 3 non-magnetic, austenitic, stainless steel |
Weight density | 7.8 g/cm3 |
Piston Material | Tungsten carbide with nickel binder |
Cylinder Material | Tungsten Carbide with cobalt binder |
Thermal Coefficient of Expansion | 11 ppm/°C |
General |
|
Test port adapters | 9/16 – 18 UNF (Autoclave); 3/8 BSP; 1/2 BSP & 3/4 BSP |
Instrument Weight | 66 lbs. (30 Kg) Instrument Base only |
Instrument Size | 18 in. X 13.5 in. X 19 in. (455 X 340 X 478 mm) |
Reservoir Volume | 235 cc (14.3 cu.in.) |
Intensifier ratio | 7 to 1 |
Seal Materials | Nitrile |
Operating Fluid | Dioctyl Sebacate (DOS), our reference 55-600 |
Options |
|
Presscal software | Windows based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Supports additional 12 pressure units (bar, mbar, MPa, kPa, psi, kg/cm2, atm, in H2O, mH2O, mmH2O, inHg, mmHg). |
Conversion Weight Sets | For applications that require nominal pressure increments in measurement units different than the main unit, conversion weight sets are available. Available measurement units are: PSI, bar kgf/cm2 or MPa. |
Accessory | Description |
---|---|
PressCal Software |
PressCal Software |
Conversion Weight Sets |
For applications that require nominal pressure increments in measurement units different than the main unit, conversion weight sets are available. |
P5551 Pointer Remover / Punch |
This tool is designed to quickly remove and consistently refit the pointer of a pressure gauge. |
Product Manuals |
---|
Brochures |
---|
Application Notes |
---|
Data Sheets |
---|
Papers / Articles |
---|
Video |
---|
Measuring Pressure with a Deadweight Tester |
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
Fluke Oil Deadweight Testers
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 4185566, 4185575, 4185582, 4185594, 4185608, 4185613, 4185624, 4185636, 4185649)
- Pressure ranges to 60,000 psi (4000 bar)
- Select from two accuracy classes; 0.02% or 0.015% of reading
- Includes hand pump and intensifier for generating high pressures
- Tungsten carbide piston and cylinder provides long term stability and durability
- Mass set can be trimmed to local gravity FOC
The Pressurements P3800 Series High Pressure Hydraulic Deadweight Testers are the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features and options designed to improve accuracy, increase reliability, and simplify operation, the P3800 Series can be used to calibrate virtually any high pressure sensing device including transducers, transmitters, gauges, pressure switches or other calibrators.
Three models are available, P3830, P3840 and P3860 offering pressure ranges of 30,000, 40,000 and 60,000 psi respectively (2000, 3000 and 4000 bar). All models are available in two accuracy classes, 0.02% or 0.015% of Reading. The Series P3800 offers an accurate and economical approach to calibrating high pressure devices.
Models & Accessories
Specifications
Pressure Ranges |
|
P3830 | 500 to 30,000 psi, or 40 to 2,000 bar, or 4 to 200 MPa, or 40 to 2000 kgf/cm2 |
P3840 | 500 to 40,000 psi, or 40 to 2,600 bar, or 4 to 260 MPa, or 40 to 2600 kgf/cm2 |
P3860 | 500 to 60,000 psi or 40 to 4,000 bar or 4 to 400 MPa or 40 to 4000 kgf/cm2 |
Accuracy |
|
Accuracy* | Standard accuracy is 0.02% of Reading*. Optional accuracy of 0.015% of Reading is available. ISO/IEC 17025 accredited calibration is provided with each instrument. *Accuracy is based on % of Reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10%, ± (accuracy class) x 10% of the piston range. See the “Guide for the Uncertainty Analysis in Pressure when Using P3000 Series Deadweight Testers” technical note for more information. |
Materials of Construction |
|
Standard weight material | Series 3 non-magnetic, austenitic, stainless steel |
Weight density | 7.8 g/cm3 |
Piston Material | Tungsten carbide with nickel binder |
Cylinder Material | Tungsten Carbide with cobalt binder |
Thermal Coefficient of Expansion | 11 ppm/°C |
General |
|
Test port adapters | 9/16 – 18 UNF (Autoclave); 3/8 BSP; 1/2 BSP & 3/4 BSP |
Instrument Weight | 66 lbs. (30 Kg) Instrument Base only |
Instrument Size | 18 in. X 13.5 in. X 19 in. (455 X 340 X 478 mm) |
Reservoir Volume | 235 cc (14.3 cu.in.) |
Intensifier ratio | 7 to 1 |
Seal Materials | Nitrile |
Operating Fluid | Dioctyl Sebacate (DOS), our reference 55-600 |
Options |
|
Presscal software | Windows based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Supports additional 12 pressure units (bar, mbar, MPa, kPa, psi, kg/cm2, atm, in H2O, mH2O, mmH2O, inHg, mmHg). |
Conversion Weight Sets | For applications that require nominal pressure increments in measurement units different than the main unit, conversion weight sets are available. Available measurement units are: PSI, bar kgf/cm2 or MPa. |
Accessory | Description |
---|---|
PressCal Software |
PressCal Software |
Conversion Weight Sets |
For applications that require nominal pressure increments in measurement units different than the main unit, conversion weight sets are available. |
P5551 Pointer Remover / Punch |
This tool is designed to quickly remove and consistently refit the pointer of a pressure gauge. |
Product Manuals |
---|
Brochures |
---|
Application Notes |
---|
Data Sheets |
---|
Papers / Articles |
---|
Video |
---|
Measuring Pressure with a Deadweight Tester |
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.