9142 Field Metrology Small dry wells for big field applications
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 3054130, 3054153, 3054175, 3054194, 3054215, 3054232, 3054259, 3054271, 3054314, 3054338, 3054350, 3054377, 3054392, 3054419)
Small dry wells for big field applications
The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.
High performance for the industrial environment
Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.
Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.
FEATURES
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
MODEL SPECIFICATIONS
Fluke 9142-A-156
Insert “A”, imperial misc. holes
–25°C to 150°C
Fluke 9142-B-156
Insert “B”, imperial comparison holes
–25°C to 150°C
Fluke 9142-C-156
Insert “C”, 0.25-inch holes
–25°C to 150°C
Fluke 9142-D-156
Insert “D”, metric comparison holes
–25°C to 150°C
Fluke 9142-E-156
Insert “E”, metric misc. holes w/ 0.25-inch hole
–25°C to 150°C
Fluke 9142-F-156
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
–25°C to 150°C
Fluke 9142-DW-156
Insert “D”, metric comparison holes
–25°C to 150°C
Fluke 9142-A-P-156
Insert “A”, imperial misc. holes
–25°C to 150°C, w/ process electronics
Fluke 9142-B-P-156
Insert “B”, Imperial comparison holes
–25°C to 150°C, w/ process electronics
Fluke 9142-C-P-156
Insert “C”, 0.25-inch holes
–25°C to 150°C, w/ process electronics
Fluke 9142-D-P-156
Insert “D”, metric comparison holes
–25°C to 150°C, w/ process electronics
Fluke 9142-E-P-156
Insert “E”, metric misc. holes w/ 0.25-inch hole
–25°C to 150°C, w/ process electronics
Fluke 9142-F-P-156
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
–25°C to 150°C, w/ process electronics
Fluke 9142-DW-P-156
No insert
–25°C to 150°C, w/ process electronics
GENERAL SPECIFICATIONS
Temperature range at 23°C | –25°C to 150°C (–13°F to 302°F) |
Display accuracy | ±0.2°C full range |
Stability | ±0.01°C full range |
Axial uniformity at 40 mm (1.6 in) | ±0.05°C full range |
Radial uniformity | ±0.01°C full range |
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) | ±0.006°C full range |
Hysteresis | 0.025 |
Operating conditions | 0°C to 50°C, 0% to 90% RH (non-condensing) |
Environmental conditions (for all specifications except temperature range) | 13°C to 33°C |
Immersion (well) Depth | 150 mm (5.9 in) |
Insert OD | 30 mm (1.18 in) |
Heating time | 16 min: 23°C to 140°C 23 min: 23°C to 150°C 25 min: –25°C to 150°C |
Cooling time | 15 min: 23°C to –25°C 25 min: 150°C to –23°C |
Resolution | 0.01° |
Display | LCD, °C or °F user-selectable |
Size (H x W x D) | 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in) |
Weight | 8.16 kg (18 lb) |
Power requirements | 100 V to 115 V (±10%) 50/60 Hz, 635 W 230 V (±10%) 50/60 Hz, 575 W |
Computer interface | RS-232 interface |
Calibration | NVLAP accredited calibration included |
Automation | Use the 1586A Super-DAQ to automate temperature sensor calibration |
-P Specifications | |
Built-in reference thermometer readout accuracy (4-Wire Reference Probe)1 | ±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C |
Reference resistance range | 0 ohms to 400 ohms |
Reference resistance accuracy2 | 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading |
Reference characterizations | ITS-90, CVD, IEC-751, Resistance |
Reference measurement capability | 4-wire |
Reference probe connection | 6-pin Din with Infocon Technology |
Built-in RTD thermometer readout accuracy | NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C |
RTD resistance range | 0 ohms to 400 ohms |
RTD resistance accuracy2 | 0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading |
RTD characterizations | PT-100 (385),(JIS),(3926), NI-120, Resistance |
RTD measurement capability | 4-wire RTD (2-,3-wire RTD w/ Jumpers only) |
RTD connection | 4 terminal input |
Built-in TC thermometer readout accuracy | Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C |
TC millivolt range | –10 mV to 75 mV |
Voltage accuracy | 0.025% of reading + 0.01 mV |
Internal cold junction compensation accuracy | ±0.35°C (ambient of 13°C to 33°C) |
TC connection | Small connectors |
Built-in mA readout accuracy | 0.02% of reading + 2 mV |
mA range | Cal 4-22 mA, Spec 4-24 mA |
mA connection | 2 terminal input |
Loop power function | 24 V DC loop power |
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C) | ±0.005% of range per °C |
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. |
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
9142 Field Metrology Small dry wells for big field applications
(Fluke Registration required before purchase. Please contact Laserman for more information on +61 8 9335 1718 )
(item no. 3054130, 3054153, 3054175, 3054194, 3054215, 3054232, 3054259, 3054271, 3054314, 3054338, 3054350, 3054377, 3054392, 3054419)
Small dry wells for big field applications
The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the “process” option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4–20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144—each with a “process” option) cover the wide range of –25 °C to 660 °C.
High performance for the industrial environment
Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.
Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 °C to 33 °C.
FEATURES
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
MODEL SPECIFICATIONS
Fluke 9142-A-156
Insert “A”, imperial misc. holes
–25°C to 150°C
Fluke 9142-B-156
Insert “B”, imperial comparison holes
–25°C to 150°C
Fluke 9142-C-156
Insert “C”, 0.25-inch holes
–25°C to 150°C
Fluke 9142-D-156
Insert “D”, metric comparison holes
–25°C to 150°C
Fluke 9142-E-156
Insert “E”, metric misc. holes w/ 0.25-inch hole
–25°C to 150°C
Fluke 9142-F-156
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
–25°C to 150°C
Fluke 9142-DW-156
Insert “D”, metric comparison holes
–25°C to 150°C
Fluke 9142-A-P-156
Insert “A”, imperial misc. holes
–25°C to 150°C, w/ process electronics
Fluke 9142-B-P-156
Insert “B”, Imperial comparison holes
–25°C to 150°C, w/ process electronics
Fluke 9142-C-P-156
Insert “C”, 0.25-inch holes
–25°C to 150°C, w/ process electronics
Fluke 9142-D-P-156
Insert “D”, metric comparison holes
–25°C to 150°C, w/ process electronics
Fluke 9142-E-P-156
Insert “E”, metric misc. holes w/ 0.25-inch hole
–25°C to 150°C, w/ process electronics
Fluke 9142-F-P-156
Insert “F”, metric comparison misc. holes w/ 0.25-inch hole
–25°C to 150°C, w/ process electronics
Fluke 9142-DW-P-156
No insert
–25°C to 150°C, w/ process electronics
GENERAL SPECIFICATIONS
Temperature range at 23°C | –25°C to 150°C (–13°F to 302°F) |
Display accuracy | ±0.2°C full range |
Stability | ±0.01°C full range |
Axial uniformity at 40 mm (1.6 in) | ±0.05°C full range |
Radial uniformity | ±0.01°C full range |
Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) | ±0.006°C full range |
Hysteresis | 0.025 |
Operating conditions | 0°C to 50°C, 0% to 90% RH (non-condensing) |
Environmental conditions (for all specifications except temperature range) | 13°C to 33°C |
Immersion (well) Depth | 150 mm (5.9 in) |
Insert OD | 30 mm (1.18 in) |
Heating time | 16 min: 23°C to 140°C 23 min: 23°C to 150°C 25 min: –25°C to 150°C |
Cooling time | 15 min: 23°C to –25°C 25 min: 150°C to –23°C |
Resolution | 0.01° |
Display | LCD, °C or °F user-selectable |
Size (H x W x D) | 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in) |
Weight | 8.16 kg (18 lb) |
Power requirements | 100 V to 115 V (±10%) 50/60 Hz, 635 W 230 V (±10%) 50/60 Hz, 575 W |
Computer interface | RS-232 interface |
Calibration | NVLAP accredited calibration included |
Automation | Use the 1586A Super-DAQ to automate temperature sensor calibration |
-P Specifications | |
Built-in reference thermometer readout accuracy (4-Wire Reference Probe)1 | ±0.010°C at -25°C ±0.015°C at 0°C ±0.020°C at 50°C ±0.025°C at 150°C ±0.030°C at 200°C ±0.040°C at 350°C ±0.050°C at 420°C ±0.070°C at 660°C |
Reference resistance range | 0 ohms to 400 ohms |
Reference resistance accuracy2 | 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading |
Reference characterizations | ITS-90, CVD, IEC-751, Resistance |
Reference measurement capability | 4-wire |
Reference probe connection | 6-pin Din with Infocon Technology |
Built-in RTD thermometer readout accuracy | NI-120: ±0.015°C at 0°C PT-100 (385): ±0.02°C at 0°C PT-100 (3926): ±0.02°C at 0°C PT-100 (JIS): ±0.02°C at 0°C |
RTD resistance range | 0 ohms to 400 ohms |
RTD resistance accuracy2 | 0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading |
RTD characterizations | PT-100 (385),(JIS),(3926), NI-120, Resistance |
RTD measurement capability | 4-wire RTD (2-,3-wire RTD w/ Jumpers only) |
RTD connection | 4 terminal input |
Built-in TC thermometer readout accuracy | Type J: ±0.7°C at 660°C Type K: ±0.8°C at 660°C Type T: ±0.8°C at 400°C Type E: ±0.7°C at 660°C Type R: ±1.4°C at 660°C Type S: ±1.5°C at 660°C Type M: ±1.4°C at 660°C Type L: ±0.7°C at 660°C Type U: ±0.75°C at 600°C Type N: ±0.9°C at 660°C Type C: ±1.1°C at 660°C |
TC millivolt range | –10 mV to 75 mV |
Voltage accuracy | 0.025% of reading + 0.01 mV |
Internal cold junction compensation accuracy | ±0.35°C (ambient of 13°C to 33°C) |
TC connection | Small connectors |
Built-in mA readout accuracy | 0.02% of reading + 2 mV |
mA range | Cal 4-22 mA, Spec 4-24 mA |
mA connection | 2 terminal input |
Loop power function | 24 V DC loop power |
Built-in electronics temperature coefficient (0°C to 13°C, 33°C to 50°C) | ±0.005% of range per °C |
1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. |
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.