Fluke 714B RTD Calibrator provides highly accurate, easy-to-use, single-function RTD temperature calibration
Fluke 712B RTD Calibrator is a handheld, battery-operated instrument that measures and sources a variety of RTD types and resistances. It also includes an isolated channel to measure 4-20 mA whiles sourcing a temperature signal. It offers configurable 0% and 100% source settings for quick 25% linearity checks. It also provides linear ramp and 25% step auto ramp functionality based on 0% and 100% settings.
Add to that dual inputs, an easy to view backlit display, plus the ability to memorize settings at power down for easy restart make the 712B the ideal test tool for temperature calibration professionals who want a highly accurate, easy-to-use, single function RTD temperature calibrator.
Features
- Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
- Measures and simulates 13 different RTD types and resistance
- Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Comes with a magnetic hanging tool designed in for convenient hands-free operation
- Features configurable 0% and 100% source settings for quick 25% linearity check
Other useful features:
- Dual inputs and backlit display for easy interpretation of measurements
- Remembers power down settings to easily restart tests when powered up
- Provides linear ramp and 25% step auto ramp based on 0% and 100% settings
- Provides one-year and two-year specifications and traceable certification of calibration
Specifications: Fluke 712B RTD Calibrators
General Specifications | ||||||
Maximum voltage applied between any terminal and earth ground or between any two terminals | 30 V | |||||
Operating temperature | -10°C to 50°C | |||||
Storage temperature | -30°C to 60°C | |||||
Operating altitude | 2,000 m | |||||
Storage altitude | 12,000 m | |||||
Relative humidity (% RH operating without condensation) | Non condensing | |||||
90% (10°C to 30°C) | ||||||
75% (30°C to 40°C) | ||||||
45% (40°C to 50°C) | ||||||
(Without condensation) | ||||||
Vibration requirements | MIL-T-28800E, Class 2 | |||||
Drop text requirements | 1 m | |||||
IP Rating | IEC 60529: IP52 | |||||
Electromagnetic environment | IEC 61326-1, Portable | |||||
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 | |||||
Power supply | 4 AA NEDA 1.5A IEC LR6 batteries | |||||
Size (H x W x L) | 52.5 x 84 x 188.5 mm | |||||
Weight | 515 g | |||||
DC mA Measurement | ||||||
Resolution | 0-24 mA | |||||
Range | 0.001 mA | |||||
Accuracy (% of reading + counts) | 0.010% + 2 μA | |||||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( < 18°C or >28°C) | |||||
Ohms Measurement | ||||||
Ohms range | Accuracy (% of reading +counts) | |||||
0.00 Ω to 400.00 Ω | 0.015% + 0.05 Ω | |||||
400.0 Ω to 4000.0 Ω | 0.015% + 0.5 Ω | |||||
Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications. | ||||||
Temperature coefficient | ±(0.002% of reading + 0.002% of range) / °C (< 18°C or > 28°C) | |||||
Ohms Source | ||||||
Ohms range | 1.0 Ω to 400.0 Ω | |||||
1.00 Ω to 400.00 Ω | ||||||
400.0 Ω to 1500.0 Ω | ||||||
1500.0 Ω to 4000.0 Ω | ||||||
Excitation current from measurement device | 0.1 mA to 0.5 mA | |||||
0.5 mA to 3 mA | ||||||
0.05 mA to 0.8 mA | ||||||
0.05 mA to 0.4 mA | ||||||
Accuracy (% of reading + counts) | 0.015% + 0.1 Ω | |||||
0.015% + 0.05 Ω | ||||||
0.015% + 0.5 Ω | ||||||
0.015% + 0.5 Ω | ||||||
Resolution | 0.00 Ω to 400.00 Ω | 0.01 Ω | ||||
400.0 Ω to 4000.0 Ω | 0.1 Ω | |||||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( <18°C or >28°C) Supports pulsed transmitters and PLCs with pulse times as short as 5 ms |
|||||
RTD Input and Output | ||||||
RTD Type (α) | Range (°C) | Measure (°C) | Source (°C) | |||
1-year | 2-year | Source current | 1-year | 2-year | ||
10 Ω Pt (385) | -200 to 100°C | 1.5°C | 3°C | 1 mA | 1.5°C | 3°C |
100 to 800°C | 1.8°C | 3.6°C | 1 mA | 1.8°C | 3.6°C | |
50 Ω Pt (385) | -200 to 100°C | 0.4°C | 0.7°C | 1 mA | 0.4°C | 0.7°C |
100 to 800°C | 0.5°C | 0.8°C | 1 mA | 0.5°C | 0.8°C | |
100 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
100 to 800°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
200 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 500 μA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
500 μA | 0.015% +0.18°C |
0.03% +0.36°C |
|
500 Ω Pt (385) | -200 to 100°C | 0.3°C | 0.6°C | 250 μA | 0.3°C | 0.6°C |
100 to 630°C | 0.015% +0.28°C |
0.03% +0.56°C |
250 μA | 0.015% +0.28°C |
0.03% +0.56°C |
|
1000 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 250 μA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
250 μA | 0.015% +0.18°C |
0.03% +0.36°C |
|
100 Ω Pt (3916) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
100 Ω Pt (3926) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
10 Ω Cu (427) | -100 to 260°C | 1.5°C | 3°C | 1 mA | 1.5°C | 3°C |
120 Ω Ni (672) | -80 to 260°C | 0.15°C | 0.3°C | 1 mA | 0.15°C | 0.3°C |
50 Ω Cu (427) | -180 to 200°C | 0.4°C | 0.7°C | 1 mA | 0.4°C | 0.7°C |
100 Ω Cu (427) | -180 to 200°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
YSI400 | 15 to 50°C | 0.2°C | 0.4°C | 250 μA | 0.2°C | 0.4°C |
1. Sensor inaccuracies not included. 2. Resolution: 0.1°C. 3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0°C (Pt10 and Cu10), 0.6°C (Pt50 and Cu50), 0.4°C (Other RTD types) to the specifications. 4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range). 5. Temperature Coefficient: ±0.05°C /°C for measure, ±0.05°C /°C (< 18°C or > 28°C) for source. 6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms. |
Includes:
- Magnetic hanging tool
- Batteries
- Manual
- Traceable calibration certificate
- Test Leads
Manuals
- 712B | Users manual
- 712B | Users manual supplement
- 712C | Users manual
- 712C | Users manual supplement
- 714B | Users manual
- 714B | Users manual supplement
- 714C | Users manual
- 714C | Users manual supplement
- 712B | Quick reference guide
- 712B/714B | Statement of memory volatility
- 712B/714B | Safety sheet
- 712B/714B | Safety sheet supplement
- 712B/714B | Calibration manual
- 712C | Quick reference guide
- 712C/714C | Safety sheet
- 714B | Quick reference guide
- 714C | Quick reference guide
- 714C | Quick reference guide supplement
Data Sheets
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
Fluke 714B RTD Calibrator provides highly accurate, easy-to-use, single-function RTD temperature calibration
Fluke 712B RTD Calibrator is a handheld, battery-operated instrument that measures and sources a variety of RTD types and resistances. It also includes an isolated channel to measure 4-20 mA whiles sourcing a temperature signal. It offers configurable 0% and 100% source settings for quick 25% linearity checks. It also provides linear ramp and 25% step auto ramp functionality based on 0% and 100% settings.
Add to that dual inputs, an easy to view backlit display, plus the ability to memorize settings at power down for easy restart make the 712B the ideal test tool for temperature calibration professionals who want a highly accurate, easy-to-use, single function RTD temperature calibrator.
Features
- Highly accurate, full-featured , easy-to-use single function RTD temperature calibrator
- Measures and simulates 13 different RTD types and resistance
- Measures 4 to 20 mA signals while simultaneously sourcing a temperature signal
- Comes with a magnetic hanging tool designed in for convenient hands-free operation
- Features configurable 0% and 100% source settings for quick 25% linearity check
Other useful features:
- Dual inputs and backlit display for easy interpretation of measurements
- Remembers power down settings to easily restart tests when powered up
- Provides linear ramp and 25% step auto ramp based on 0% and 100% settings
- Provides one-year and two-year specifications and traceable certification of calibration
Specifications: Fluke 712B RTD Calibrators
General Specifications | ||||||
Maximum voltage applied between any terminal and earth ground or between any two terminals | 30 V | |||||
Operating temperature | -10°C to 50°C | |||||
Storage temperature | -30°C to 60°C | |||||
Operating altitude | 2,000 m | |||||
Storage altitude | 12,000 m | |||||
Relative humidity (% RH operating without condensation) | Non condensing | |||||
90% (10°C to 30°C) | ||||||
75% (30°C to 40°C) | ||||||
45% (40°C to 50°C) | ||||||
(Without condensation) | ||||||
Vibration requirements | MIL-T-28800E, Class 2 | |||||
Drop text requirements | 1 m | |||||
IP Rating | IEC 60529: IP52 | |||||
Electromagnetic environment | IEC 61326-1, Portable | |||||
Safety | IEC 61010-1, Max 30 V to earth, Pollution Degree 2 | |||||
Power supply | 4 AA NEDA 1.5A IEC LR6 batteries | |||||
Size (H x W x L) | 52.5 x 84 x 188.5 mm | |||||
Weight | 515 g | |||||
DC mA Measurement | ||||||
Resolution | 0-24 mA | |||||
Range | 0.001 mA | |||||
Accuracy (% of reading + counts) | 0.010% + 2 μA | |||||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( < 18°C or >28°C) | |||||
Ohms Measurement | ||||||
Ohms range | Accuracy (% of reading +counts) | |||||
0.00 Ω to 400.00 Ω | 0.015% + 0.05 Ω | |||||
400.0 Ω to 4000.0 Ω | 0.015% + 0.5 Ω | |||||
Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications. | ||||||
Temperature coefficient | ±(0.002% of reading + 0.002% of range) / °C (< 18°C or > 28°C) | |||||
Ohms Source | ||||||
Ohms range | 1.0 Ω to 400.0 Ω | |||||
1.00 Ω to 400.00 Ω | ||||||
400.0 Ω to 1500.0 Ω | ||||||
1500.0 Ω to 4000.0 Ω | ||||||
Excitation current from measurement device | 0.1 mA to 0.5 mA | |||||
0.5 mA to 3 mA | ||||||
0.05 mA to 0.8 mA | ||||||
0.05 mA to 0.4 mA | ||||||
Accuracy (% of reading + counts) | 0.015% + 0.1 Ω | |||||
0.015% + 0.05 Ω | ||||||
0.015% + 0.5 Ω | ||||||
0.015% + 0.5 Ω | ||||||
Resolution | 0.00 Ω to 400.00 Ω | 0.01 Ω | ||||
400.0 Ω to 4000.0 Ω | 0.1 Ω | |||||
Temperature coefficient | ± (0.002% of reading + 0.002% of range) /°C ( <18°C or >28°C) Supports pulsed transmitters and PLCs with pulse times as short as 5 ms |
|||||
RTD Input and Output | ||||||
RTD Type (α) | Range (°C) | Measure (°C) | Source (°C) | |||
1-year | 2-year | Source current | 1-year | 2-year | ||
10 Ω Pt (385) | -200 to 100°C | 1.5°C | 3°C | 1 mA | 1.5°C | 3°C |
100 to 800°C | 1.8°C | 3.6°C | 1 mA | 1.8°C | 3.6°C | |
50 Ω Pt (385) | -200 to 100°C | 0.4°C | 0.7°C | 1 mA | 0.4°C | 0.7°C |
100 to 800°C | 0.5°C | 0.8°C | 1 mA | 0.5°C | 0.8°C | |
100 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
100 to 800°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
200 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 500 μA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
500 μA | 0.015% +0.18°C |
0.03% +0.36°C |
|
500 Ω Pt (385) | -200 to 100°C | 0.3°C | 0.6°C | 250 μA | 0.3°C | 0.6°C |
100 to 630°C | 0.015% +0.28°C |
0.03% +0.56°C |
250 μA | 0.015% +0.28°C |
0.03% +0.56°C |
|
1000 Ω Pt (385) | -200 to 100°C | 0.2°C | 0.4°C | 250 μA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
250 μA | 0.015% +0.18°C |
0.03% +0.36°C |
|
100 Ω Pt (3916) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
100 Ω Pt (3926) | -200 to 100°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
100 to 630°C | 0.015% +0.18°C |
0.03% +0.36°C |
1 mA | 0.015% +0.18°C |
0.03% +0.36°C |
|
10 Ω Cu (427) | -100 to 260°C | 1.5°C | 3°C | 1 mA | 1.5°C | 3°C |
120 Ω Ni (672) | -80 to 260°C | 0.15°C | 0.3°C | 1 mA | 0.15°C | 0.3°C |
50 Ω Cu (427) | -180 to 200°C | 0.4°C | 0.7°C | 1 mA | 0.4°C | 0.7°C |
100 Ω Cu (427) | -180 to 200°C | 0.2°C | 0.4°C | 1 mA | 0.2°C | 0.4°C |
YSI400 | 15 to 50°C | 0.2°C | 0.4°C | 250 μA | 0.2°C | 0.4°C |
1. Sensor inaccuracies not included. 2. Resolution: 0.1°C. 3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0°C (Pt10 and Cu10), 0.6°C (Pt50 and Cu50), 0.4°C (Other RTD types) to the specifications. 4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range). 5. Temperature Coefficient: ±0.05°C /°C for measure, ±0.05°C /°C (< 18°C or > 28°C) for source. 6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms. |
Includes:
- Magnetic hanging tool
- Batteries
- Manual
- Traceable calibration certificate
- Test Leads
Manuals
- 712B | Users manual
- 712B | Users manual supplement
- 712C | Users manual
- 712C | Users manual supplement
- 714B | Users manual
- 714B | Users manual supplement
- 714C | Users manual
- 714C | Users manual supplement
- 712B | Quick reference guide
- 712B/714B | Statement of memory volatility
- 712B/714B | Safety sheet
- 712B/714B | Safety sheet supplement
- 712B/714B | Calibration manual
- 712C | Quick reference guide
- 712C/714C | Safety sheet
- 714B | Quick reference guide
- 714C | Quick reference guide
- 714C | Quick reference guide supplement
Data Sheets
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.