The Amprobe ACD-40 provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.
THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100%
Features
- True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
- Total harmonics distortion (THD), AC/DC voltage up to 600V, AC current up to 1000A, resistance, frequency, temperature
- Peak hold
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Auto power off
- Automatic polarity
- Low battery indication
- Data hold
- Large, easy to read LCD display with backlight
- Accommodates conductors up to 1.77 (45mm) in diameter
- Carrying case, test leads, batteries (installed), thermocouple and manual included
- Voltage overload protection for all functions up to 600V AC/DC
Specifications
FEATURE | ACD-41PQ | ACD-45PQ |
True-rms | • | |
AC Current | 40.00 A, 400.0 A, 1000 A | 40.00 A, 400.0 A, 600 A |
AC/DC Voltage | 600.0 V | |
Resistance | 999.9 Ω | |
Continuity | • | |
Temperature | -58 °F → 572 °F (-50 °C → 300 °C) | - |
Frequency | 5.00 Hz → 500.0 Hz | |
Active power | (W) 0 kW → 600.0 kW | 0 kW → 360.0 kW |
Reactive power (VAR) | 0 kVAR → 600.0 kVAR | 0 kVAR → 360.0 kVAR |
Apparent power (VA) | 0 kVA → 600.0 kVA | 0 kVA → 360.0 kVA |
Power Factor | 0.10 → 0.99 | |
Energy (KWHr) | • | • |
Total Harmonic Distortion (THD%) | 0.0 % → 99 % | - |
Accommodates Conductors | up to 1.77" (45 mm) in diameter | up to 1.02" (26 mm) in diameter |
Specifications | |
TRMS: | YES |
AC Current: | 40.0 / 400.0 / 1000 A |
AC Current Basic Accuracy: | +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
DC Voltage: | 600.0V |
DC Voltage Basic Accuracy: | +/-(0.5% Rdg + 5 LSD) |
AC Voltage: | 600.0V |
AC Voltage Basic Accuracy: | +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
Resistance: | 999.9O |
Resistance Basic Accuracy: | +/-(1.0% Rdg + 6 LSD) |
Frequency: | 5.00Hz to 500.0Hz |
Frequency Basic Accuracy: | +/-(0.5% Rdg +4 LSD) |
THD-F *: | 0.0% to 99.9% |
THD-F * Basic Accuracy**: | 1.5% of Reading + 6d @ Fund Frequency |
Active Power (W): | 0 to 600.0 kW |
Active Power (W) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
Reactive Power (VAR): | 0 to 600.0 kVAR |
Reactive Power (VAR) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
Apparent Power (VA): | 0 to 600.0 kVA |
Apparent Power (VA) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
Power Factor: | 0.10 to 0.99 |
Power Factor Basic Accuracy: | +/- 3 LSD @ Harmonics Fund to 21th |
Temperature: | -58°F to 572° F (-50° C to 300° C) |
Temperature Basic Accuracy: | +/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C) |
For complete specs please download the product datasheet under the “Resources" tab.
Download
Shipping | This Item Ships from Fremantle, Perth, Western Australia |
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Description
The Amprobe ACD-40 provides a simple and effective way to verify if the electrical system is affected by harmonics. Add on troubleshooting capabilities with the ACD-40PQ data-logging feature or get complete power analysis with the ACD-41PQ. Increase measuring efficiency with an optional PC interface kit.
THD-F is defined as: (Total Harmonic RMS / Fundamental RMS) x 100%
Features
- True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
- Total harmonics distortion (THD), AC/DC voltage up to 600V, AC current up to 1000A, resistance, frequency, temperature
- Peak hold
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Auto power off
- Automatic polarity
- Low battery indication
- Data hold
- Large, easy to read LCD display with backlight
- Accommodates conductors up to 1.77 (45mm) in diameter
- Carrying case, test leads, batteries (installed), thermocouple and manual included
- Voltage overload protection for all functions up to 600V AC/DC
Specifications
FEATURE | ACD-41PQ | ACD-45PQ |
True-rms | • | |
AC Current | 40.00 A, 400.0 A, 1000 A | 40.00 A, 400.0 A, 600 A |
AC/DC Voltage | 600.0 V | |
Resistance | 999.9 Ω | |
Continuity | • | |
Temperature | -58 °F → 572 °F (-50 °C → 300 °C) | - |
Frequency | 5.00 Hz → 500.0 Hz | |
Active power | (W) 0 kW → 600.0 kW | 0 kW → 360.0 kW |
Reactive power (VAR) | 0 kVAR → 600.0 kVAR | 0 kVAR → 360.0 kVAR |
Apparent power (VA) | 0 kVA → 600.0 kVA | 0 kVA → 360.0 kVA |
Power Factor | 0.10 → 0.99 | |
Energy (KWHr) | • | • |
Total Harmonic Distortion (THD%) | 0.0 % → 99 % | - |
Accommodates Conductors | up to 1.77" (45 mm) in diameter | up to 1.02" (26 mm) in diameter |
Specifications | |
TRMS: | YES |
AC Current: | 40.0 / 400.0 / 1000 A |
AC Current Basic Accuracy: | +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
DC Voltage: | 600.0V |
DC Voltage Basic Accuracy: | +/-(0.5% Rdg + 5 LSD) |
AC Voltage: | 600.0V |
AC Voltage Basic Accuracy: | +/-(0.5% Rdg + 5 LSD) @ 50 / 60 Hz |
Resistance: | 999.9O |
Resistance Basic Accuracy: | +/-(1.0% Rdg + 6 LSD) |
Frequency: | 5.00Hz to 500.0Hz |
Frequency Basic Accuracy: | +/-(0.5% Rdg +4 LSD) |
THD-F *: | 0.0% to 99.9% |
THD-F * Basic Accuracy**: | 1.5% of Reading + 6d @ Fund Frequency |
Active Power (W): | 0 to 600.0 kW |
Active Power (W) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
Reactive Power (VAR): | 0 to 600.0 kVAR |
Reactive Power (VAR) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th & PF > 0.7 |
Apparent Power (VA): | 0 to 600.0 kVA |
Apparent Power (VA) Basic Accuracy: | +/-(2.0% Rdg + 6 LSD) @ Harmonics Fund to 10th |
Power Factor: | 0.10 to 0.99 |
Power Factor Basic Accuracy: | +/- 3 LSD @ Harmonics Fund to 21th |
Temperature: | -58°F to 572° F (-50° C to 300° C) |
Temperature Basic Accuracy: | +/-(2.0% Rdg + 6°F) +/-(2.0 % Rdg + 3°C) |
For complete specs please download the product datasheet under the “Resources" tab.
Download
Shipping
Shipping | This item ships to |
Delivery & Returns
Please allow 2 - 10 days for your order to arrive.
Although Most Stocked Products will generally Ship Overnight. We source products from all over the world to bring you epic offers and the lowest prices. This means sometimes you have to wait a little longer to get your order but it's always worth it!
Returns are easy.
simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap!
Reviews
6 Great reasons to buy from us:
-
30 Days Return
If your product is faulty or damaged under manufacture warranty, simply send it back to us and we'll cheerfully replace it or fix the problem for you. -
Returns are Easy
Simply contact us for a returns number and send your item to our returns centre for fast processing. We'll get you a replacement or refund in a snap! -
Best Price Guarantee
In the unlikely event that you find your item cheaper at another online store, just let us know and we'll beat the competitor's pricing hands-down. -
We guarantee your satisfaction
We insist that you love everything you buy from us. If you're unhappy for any reason whatsoever, just let us know and we'll bend over backwards to make things right again. -
100% Safe & Secure
Ordering from Laserman Technologies is 100% safe and secure so you can rest easy. Your personal details are never shared, sold or rented to anyone either. -
Best Laser Warranties in the Business
Laserman the Best Laser Level, Pipe Laser and Laser Measuring Warranties in the Business - Now thats unbeatable value !!.